Literature DB >> 12173878

Real-time computerized in situ guidance system for ACL graft placement.

M Sati1, H Stäubli, Y Bourquin, M Kunz, L P Nolte.   

Abstract

A recent consensus within an international society for sports traumatology revealed that approximately 40% of ACL grafts are being surgically misplaced in current clinical practice. To help solve this problem, a computer-assisted system has been developed at the M.E. Müller Institute for Biomechanics to perform intraoperative planning and guidance of ACL replacement. Dynamic reference bases are fixed on the femur and tibia to track the knee's movement. No intraoperative imaging is required, and potential ligament attachment sites can be directly digitized using a computerized palpation hook in a minimally invasive fashion when used in conjunction with standard endoscopic tools. The palpation hook can be used by the surgeon to interactively define various anatomical structures and reference landmarks that are important for proper ligament positioning. The system can input a standard diagnostic X-ray (sagittal view of the femur) and allows intraoperative registration of this image with the patient to provide valuable X-ray landmarks for intraoperative guidance. The computer helps in situ planning of ligament placement by providing the surgeon with a 3D overview of the relevant anatomical landmarks and information on graft impingement and elongation for various simulated surgical insertions and graft sizes. After planning, the computer helps guide placement of the chosen insertion tunnels. This approach provides an augmented 3D view of knee anatomy and ligament function prior to drilling that is not possible with current procedures. The flexibility of the system in permitting surgeon-defined landmarks and free interpretation of functional factors allows it to support a variety of surgical workflows and techniques.

Entities:  

Mesh:

Year:  2002        PMID: 12173878     DOI: 10.1002/igs.10028

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  6 in total

1.  Post-operative 3D CT feedback improves accuracy and precision in the learning curve of anatomic ACL femoral tunnel placement.

Authors:  Luigi Sirleo; Massimo Innocenti; Matteo Innocenti; Roberto Civinini; Christian Carulli; Fabrizio Matassi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2017-06-19       Impact factor: 4.342

2.  Variability of landmark acquisition affects tunnel calculation in image-free ACL navigation.

Authors:  Sven Shafizadeh; Maurice Balke; Ulrich Hagn; Stefan Grote; Bertil Bouillon; Marc Banerjee
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-04-05       Impact factor: 4.342

3.  Computer-assisted navigation in ACL reconstruction is attractive but not yet cost efficient.

Authors:  Jennifer Margier; Sandra David Tchouda; Jean-Jacques Banihachemi; Jean-Luc Bosson; Stéphane Plaweski
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2014-01-21       Impact factor: 4.342

4.  Comparative study on anterior cruciate ligament reconstruction: determination of isometric points with and without navigation.

Authors:  Fabio J Angelini; Roberto F M Albuquerque; Sandra U Sasaki; Gilberto L Camanho; Arnaldo J Hernandez
Journal:  Clinics (Sao Paulo)       Date:  2010-07       Impact factor: 2.365

5.  Validation of an optical, computer-assisted technique for intraoperative tracking of 3-dimensional canine stifle joint motion.

Authors:  Cecilia Signorelli; Filippo Cinti; Stefano Zaffagnini; Luciano Pisoni; Nicola Francesco Lopomo
Journal:  Open Vet J       Date:  2020-03-22

Review 6.  Computer-Assisted Orthopedic Surgery: Current State and Future Perspective.

Authors:  Guoyan Zheng; Lutz P Nolte
Journal:  Front Surg       Date:  2015-12-23
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.