Literature DB >> 12166806

Cryostatic micro-computed tomography imaging of arterial wall perfusion.

Birgit Kantor1, Steven M Jorgensen, Patricia E Lund, Michael S Chmelik, Denise A Reyes, Erik L Ritman.   

Abstract

A double-walled copper vessel, 32 cc in volume, was fabricated for scanning tissue specimens while maintained below freezing point. To keep specimen temperature within +/- 1 degrees C, temperature sensors within the chamber control, the rate of inflow of the cold nitrogen gas vented through the chamber. The specimen is attached to a small platform on top of a vertical pin which is attached to the computer-controlled rotating stage under the vessel. The purpose of this arrangement is to permit scanning of specimens up to 2 cm3 that (1) cannot be "fixed" (e.g., with formalin) because of analyses which are incompatible with prior fixation (certain immunohistochemistry and biomolecular methods), or (2) are "snap"-frozen during a transient process, such as the accumulation and/or washout of radiopaque indicators. Examples of "cryoscans" of porcine carotid and coronary artery wall opacification in either untouched or acutely stented arteries, snap-frozen immediately after selective intra-arterial injection of a contrast agent, show accumulation of contrast in the extravascular space indicating increased endothelial permeability or endothelial and medial disruption following stent placement. The detection of contrast in the adventitia suggest that vasa vasorum deliver the contrast agent from the main lumen to the adventitial extravascular space but not to the media.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12166806     DOI: 10.1002/sca.4950240405

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  9 in total

Review 1.  Micro-computed tomography of the lungs and pulmonary-vascular system.

Authors:  Erik L Ritman
Journal:  Proc Am Thorac Soc       Date:  2005

2.  Solute transport in cyclically deformed porous tissue scaffolds with controlled pore cross-sectional geometries.

Authors:  Jorn Op Den Buijs; Lichun Lu; Steven M Jorgensen; Dan Dragomir-Daescu; Michael J Yaszemski; Erik L Ritman
Journal:  Tissue Eng Part A       Date:  2009-08       Impact factor: 3.845

3.  Small-animal CT - Its Difference from, and Impact on, Clinical CT.

Authors:  Erik L Ritman
Journal:  Nucl Instrum Methods Phys Res A       Date:  2007-10-01       Impact factor: 1.455

4.  Validation of a fluid-structure interaction model of solute transport in pores of cyclically deformed tissue scaffolds.

Authors:  Jorn Op Den Buijs; Erik L Ritman; Dan Dragomir-Daescu
Journal:  Tissue Eng Part C Methods       Date:  2010-10       Impact factor: 3.056

5.  Isolation and characterization of human osteoblasts from needle biopsies without in vitro culture.

Authors:  K Fujita; M M Roforth; E J Atkinson; J M Peterson; M T Drake; L K McCready; J N Farr; D G Monroe; S Khosla
Journal:  Osteoporos Int       Date:  2013-10-11       Impact factor: 4.507

6.  IVUS detection of vasa vasorum blood flow distribution in coronary artery vessel wall.

Authors:  Regina Moritz; Diane R Eaker; Jill L Anderson; Timothy L Kline; Steven M Jorgensen; Amir Lerman; Erik L Ritman
Journal:  JACC Cardiovasc Imaging       Date:  2012-09

7.  Changes in CT angiographic opacification of porcine coronary artery wall with patchy altered flow in vasa vasorum.

Authors:  Regina Moritz; Jill L Anderson; Andrew J Vercnocke; Robert J Wentz; Erik L Ritman
Journal:  Int J Cardiovasc Imaging       Date:  2013-02-27       Impact factor: 2.357

8.  Coronary computed tomography and magnetic resonance imaging.

Authors:  Birgit Kantor; Eike Nagel; Paul Schoenhagen; Jörg Barkhausen; Thomas C Gerber
Journal:  Curr Probl Cardiol       Date:  2009-04       Impact factor: 5.200

9.  Cyclic deformation-induced solute transport in tissue scaffolds with computer designed, interconnected, pore networks: experiments and simulations.

Authors:  Jorn Op Den Buijs; Dan Dragomir-Daescu; Erik L Ritman
Journal:  Ann Biomed Eng       Date:  2009-05-23       Impact factor: 3.934

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.