Literature DB >> 12164443

Extraction of pacemaker and implantable cardioverter defibrillator leads: patient and lead characteristics in relation to the requirement of extraction tools.

Frank Bracke1, Albert Meijer, Berry Van Gelder.   

Abstract

Effective tools for extraction of pacemaker and ICD leads have been developed in the past decennium. This study investigated the necessity of using these tools in addition to direct traction in relation to patient and lead characteristics. The study encompasses first attempts at extraction of consecutive pacemaker and ICD leads from the subpectoral area. A stepwise extraction protocol was used with traction first (directly or with a locking stylet) followed by laser sheath extraction if not successful. The indication, patient age, time from implant, fixation mechanism, location, and insertion site of the leads were studied in relation to the outcome of traction. A total of 145 leads in 83 patients were extracted. Leads were implanted for 71 +/- 61 months. Indication for extraction was infection in 96 leads and malfunction in 49 leads. There were 90 ventricular leads including 16 ICD leads. Forty-nine (34%) leads were extracted with traction; in 96 (66%) leads a laser sheath was necessary. All leads implanted for < 6 months could be removed with traction alone. In a multivariate logistic regression model, time from implant was the main factor determining success of traction (P < 0.001), but in case of infection the success rate increased (P = 0.004). In conclusion, time from implant is the decisive factor to judge the potential efficacy of lead extraction with direct traction. If leads are implanted for 6 months, the availability of additional extraction tools is necessary when lead extraction is considered. In addition to time from implant, infected leads have a better chance to be removed with traction although it is a much weaker predictor.

Entities:  

Mesh:

Year:  2002        PMID: 12164443     DOI: 10.1046/j.1460-9592.2002.01037.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  13 in total

1.  Incidence and predictors of subclavian vein obstruction following biventricular device implantation.

Authors:  Serkan Bulur; Ahmet Vural; Mehmet Yazıcı; Gökhan Ertaş; Hakan Özhan; Dilek Ural
Journal:  J Interv Card Electrophysiol       Date:  2010-10-02       Impact factor: 1.900

Review 2.  [ICD lead defects: diagnosis and therapeutical options].

Authors:  Christian G Wollmann; Dirk Böcker; Andreas Löher; Hans H Scheld; Günter Breithardt; Rainer Gradaus
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2009-02-11

Review 3.  Surgical management of cardiac implantable electronic device infections.

Authors:  Michael Koutentakis; Stavros Siminelakis; Panagiotis Korantzopoulos; Anastasios Petrou; Alexandra Petrou; Helen Priavali; Eleftheria Priavali; Andreas Mpakas; Helen Gesouli; Eleftheria Gesouli; Efstratios Apostolakis; Eleftheria Apostolakis; Kosmas Tsakiridis; Paul Zarogoulidis; Nikolaos Katsikogiannis; Ioanna Kougioumtzi; Nikolaos Machairiotis; Theodora Tsiouda; Konstantinos Zarogoulidis
Journal:  J Thorac Dis       Date:  2014-03       Impact factor: 2.895

4.  Differences in laser lead extraction of infected vs. non-infected leads.

Authors:  Simon Pecha; Liesa Castro; Julia Vogler; Matthias Linder; Nils Gosau; Stephan Willems; Hermann Reichenspurner; Samer Hakmi
Journal:  Heart Vessels       Date:  2018-04-05       Impact factor: 2.037

5.  Nanostim leadless pacemaker retrieval and simultaneous micra leadless pacemaker replacement: a single-center experience.

Authors:  Roshini S Asirvatham; Vaibhav R Vaidya; Trena M Thome; Paul A Friedman; Yong-Mei Cha
Journal:  J Interv Card Electrophysiol       Date:  2019-11-14       Impact factor: 1.900

6.  Reflections of six years of lead extraction: influence on indications and technique.

Authors:  F A Bracke; A Meijer; B van Gelder
Journal:  Neth Heart J       Date:  2004-03       Impact factor: 2.380

7.  Arrhythmia device lead extraction: factors that necessitate laser assistance.

Authors:  Lorne J Gula; Andrew D Krahn; Raymond Yee; Allan C Skanes; Nina Ghosh; George J Klein
Journal:  Can J Cardiol       Date:  2008-10       Impact factor: 5.223

Review 8.  Pacemaker and ICD leads: strategies for long-term management.

Authors:  P Peter Borek; Bruce L Wilkoff
Journal:  J Interv Card Electrophysiol       Date:  2008-04-08       Impact factor: 1.900

9.  The lead extractor's toolbox: a review of current endovascular pacemaker and ICD lead extraction techniques.

Authors:  F A Bracke
Journal:  Indian Pacing Electrophysiol J       Date:  2003-07-01

10.  Superior vena cava echocardiography as a screening tool to predict cardiovascular implantable electronic device lead fibrosis.

Authors:  S Jeffrey Yakish; Arvin Narula; Robert Foley; Andrew Kohut; Steven Kutalek
Journal:  J Cardiovasc Ultrasound       Date:  2015-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.