Literature DB >> 12160699

Three-dimensional spectral signal-to-noise ratio for a class of reconstruction algorithms.

Pawel A Penczek1.   

Abstract

A three-dimensional (3D) version of the spectral signal-to-noise ratio (SSNR)-based resolution measure is introduced. The measure is defined for a class of 3D reconstruction algorithms that use interpolation in Fourier space. The statistical properties of the SSNR are discussed and related to the properties of another resolution measure, the Fourier shell correlation (FSC). The new measure was tested on 3D structures calculated from a simulated set of quasi-evenly spaced 2D projections using a nearest-neighbor interpolation and a gridding algorithm. In the latter case, the results agree very well with the FSC-based estimate, with the exception of very high SSNR values. The main applicability of the 3D SSNR is tomography, where due to the small number of projections collected, FSC cannot be used. The new measure was applied to three sets of tomographic data. It was demonstrated that the measure is sufficiently sensitive to yield theoretically expected results. Therefore, the 3D SSNR opens up the possibility of evaluating the quality of tomographic reconstructions in an objective manner. The 3D distribution of SSNR is of major interest in single-particle analysis. It is shown that the new measure can be used to evaluate the anisotropy of 3D reconstructions. The distribution of SSNR is characterized by three anisotropy indices derived from principal axes of the 3D inertia covariance matrix of the SSNR. These indices are used to construct a 3D Fourier filter which, when applied to a 3D reconstruction of a macromolecule, maximizes the SNR in real space and minimizes real-space artifacts caused by uneven distribution of 2D projections.

Mesh:

Year:  2002        PMID: 12160699     DOI: 10.1016/s1047-8477(02)00033-3

Source DB:  PubMed          Journal:  J Struct Biol        ISSN: 1047-8477            Impact factor:   2.867


  33 in total

1.  Resolution measures in molecular electron microscopy.

Authors:  Pawel A Penczek
Journal:  Methods Enzymol       Date:  2010       Impact factor: 1.600

2.  Spectral signal-to-noise ratio and resolution assessment of 3D reconstructions.

Authors:  M Unser; C O S Sorzano; P Thévenaz; S Jonić; C El-Bez; S De Carlo; J F Conway; B L Trus
Journal:  J Struct Biol       Date:  2005-03       Impact factor: 2.867

Review 3.  Bridging the imaging gap: visualizing subcellular architecture with electron tomography.

Authors:  Sriram Subramaniam
Journal:  Curr Opin Microbiol       Date:  2005-06       Impact factor: 7.934

Review 4.  3D electron microscopy of biological nanomachines: principles and applications.

Authors:  C O S Sorzano; S Jonic; M Cottevieille; E Larquet; N Boisset; S Marco
Journal:  Eur Biophys J       Date:  2007-07-05       Impact factor: 1.733

5.  Three-dimensional volume rendering of the ankle based on magnetic resonance images enables the generation of images comparable to real anatomy.

Authors:  Giuseppe Anastasi; Giuseppina Cutroneo; Daniele Bruschetta; Fabio Trimarchi; Giuseppe Ielitro; Simona Cammaroto; Antonio Duca; Placido Bramanti; Angelo Favaloro; Gianluigi Vaccarino; Demetrio Milardi
Journal:  J Anat       Date:  2009-08-12       Impact factor: 2.610

Review 6.  Challenges and opportunities in cryo-EM single-particle analysis.

Authors:  Dmitry Lyumkis
Journal:  J Biol Chem       Date:  2019-02-25       Impact factor: 5.157

7.  Cross-Validation of Data Compatibility Between Small Angle X-ray Scattering and Cryo-Electron Microscopy.

Authors:  Jin Seob Kim; Bijan Afsari; Gregory S Chirikjian
Journal:  J Comput Biol       Date:  2016-10-06       Impact factor: 1.479

8.  Evaluating Local and Directional Resolution of Cryo-EM Density Maps.

Authors:  Sriram Aiyer; Cheng Zhang; Philp R Baldwin; Dmitry Lyumkis
Journal:  Methods Mol Biol       Date:  2021

9.  One number does not fit all: mapping local variations in resolution in cryo-EM reconstructions.

Authors:  Giovanni Cardone; J Bernard Heymann; Alasdair C Steven
Journal:  J Struct Biol       Date:  2013-08-14       Impact factor: 2.867

10.  Heterogeneity of large macromolecular complexes revealed by 3D cryo-EM variance analysis.

Authors:  Wei Zhang; Marek Kimmel; Christian M T Spahn; Pawel A Penczek
Journal:  Structure       Date:  2008-12-10       Impact factor: 5.006

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.