Literature DB >> 12147147

Comparison of vibration perception thresholds obtained with the Neurothesiometer and the CASE IV and relationship to nerve conduction studies.

Vera Bril1, B A Perkins.   

Abstract

AIMS: Vibration perception thresholds (VPTs) are used frequently to assess somatosensory pathways in clinical trials. Different equipment, testing paradigms, and stimulation sites produce varying results which make comparisons between trials and patient populations challenging. Information comparing the VPT obtained with the Neurothesiometer with that with the Vibratron is available, but not for a similar comparison with the CASE IV (computer-assisted sensory examination device).
METHODS: Subjects (n = 478) including reference, non-neuropathic subjects with diabetes mellitus (DM), and diabetic patients with mild, moderate and severe diabetic sensorimotor polyneuropathy (DSP) had VPTs measured with the CASE IV and Neurothesiometer, as well as standard sural nerve conduction studies (NCS), all performed during the same half-day. The dorsum of the foot was used as the site of stimulation for the CASE IV VPT determination and the distal phalanx of the first toe for the Neurothesiometer.
RESULTS: VPTs by the CASE IV and the Neurothesiometer compared moderately by linear regression analyses (R2 = 0.547, P < 0.0001), and by 95% confidence intervals. Sensitivity for the diagnosis of mild DSP was 70% with the Neurothesiometer and 49% with the CASE IV. VPTs determined by either the Neurothesiometer or the CASE IV correlated with similar agreement to the sural nerve action potential amplitude as determined by nerve conduction studies (NCS) (R2 = 0.456 and 0.461, respectively, P < 0.0001).
CONCLUSIONS: The results demonstrated a significant correlation of VPT values in different stages of DSP obtained by the two methods. The Neurothesiometer was more sensitive for the diagnosis of DSP, particularly in those with mild neuropathy. Similar correlations between VPTs and electrophysiological parameters were observed, indicating that both methods are valid, and thus the Neurothesiometer may be preferable due to the ease and rapidity of testing by this method.

Entities:  

Mesh:

Year:  2002        PMID: 12147147     DOI: 10.1046/j.1464-5491.2002.00759.x

Source DB:  PubMed          Journal:  Diabet Med        ISSN: 0742-3071            Impact factor:   4.359


  14 in total

1.  Screening patients at risk for diabetic foot ulceration: a comparison between measurement of vibration perception threshold and 10-g monofilament test.

Authors:  Jean-Louis Richard; Lise Reilhes; Stéphanie Buvry; Monique Goletto; Jean-Luc Faillie
Journal:  Int Wound J       Date:  2012-08-14       Impact factor: 3.315

2.  The steel ball-bearing test: a new test for evaluating protective sensation in the diabetic foot.

Authors:  N Papanas; A Gries; E Maltezos; R Zick
Journal:  Diabetologia       Date:  2006-01-20       Impact factor: 10.122

3.  Vibration perception threshold as a measure of distal symmetrical peripheral neuropathy in type 1 diabetes: results from the DCCT/EDIC study.

Authors:  Catherine L Martin; Barbara H Waberski; Rodica Pop-Busui; Patricia A Cleary; Sarah Catton; James W Albers; Eva L Feldman; William H Herman
Journal:  Diabetes Care       Date:  2010-09-10       Impact factor: 19.112

4.  Interrater Reliability of Four Sensory Measures in People with Multiple Sclerosis.

Authors:  Marcin Uszynski; Helen Purtill; Susan Coote
Journal:  Int J MS Care       Date:  2016 Mar-Apr

Review 5.  How to diagnose neuropathic pain? The contribution from clinical examination, pain questionnaires and diagnostic tests.

Authors:  S La Cesa; S Tamburin; V Tugnoli; G Sandrini; S Paolucci; M Lacerenza; P Marchettini; G Cruccu; A Truini
Journal:  Neurol Sci       Date:  2015-09-26       Impact factor: 3.307

Review 6.  Distal Sensorimotor Neuropathy: Improvements in Diagnosis.

Authors:  Prashanth R J Vas; Sanjeev Sharma; Gerry Rayman
Journal:  Rev Diabet Stud       Date:  2015-08-10

7.  NerveCheck: An inexpensive quantitative sensory testing device for patients with diabetic neuropathy.

Authors:  G Ponirakis; M N Odriozola; S Odriozola; I N Petropoulos; S Azmi; H Fadavi; U Alam; O Asghar; A Marshall; A Miro; A Kheyami; A Al-Ahmar; M B Odriozola; A Odriozola; R A Malik
Journal:  Diabetes Res Clin Pract       Date:  2016-01-14       Impact factor: 5.602

Review 8.  ViibraTip for Testing Vibration Perception to Detect Diabetic Peripheral Neuropathy: A NICE Medical Technology Guidance.

Authors:  Iain Willits; Helen Cole; Roseanne Jones; Paul Dimmock; Mick Arber; Joyce Craig; Andrew Sims
Journal:  Appl Health Econ Health Policy       Date:  2015-08       Impact factor: 2.561

9.  Arterial Stiffness Is Associated with Peripheral Sensory Neuropathy in Diabetes Patients in Ghana.

Authors:  Kwame Yeboah; Jennifer A Agyekum; Richard N A Owusu Mensah; Patrick K Affrim; Linda Adu-Gyamfi; Rita O Doughan; Afua B Adjei
Journal:  J Diabetes Res       Date:  2018-01-31       Impact factor: 4.011

10.  Elevated Vibration Perception Thresholds in CIDP Patients Indicate More Severe Neuropathy and Lower Treatment Response Rates.

Authors:  Alon Abraham; Hana Albulaihe; Majed Alabdali; Mohammad Qrimli; Ari Breiner; Carolina Barnett; Hans D Katzberg; Leif E Lovblom; Bruce A Perkins; Vera Bril
Journal:  PLoS One       Date:  2015-11-06       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.