Literature DB >> 12135256

Implantable loop recorder undersensing mimicking complete heart block.

S I Chrysostomakis1, E N Simantirakis, M E Marketou, P E Vardas.   

Abstract

The newer implantable loop recorders recently introduced (Reveal Plus. Medtronic Inc, Minneapolis, MN, U.S.A.). equipped with auto activation capabilities, are expected to expand our diagnostic abilities in the investigation of syncopal episodes. The case presented here is that of a man with pre-syncopal and syncopal episodes, without organic heart disease, in whom the device was auto-activated due to undersensing and the recorded strip imitated complete heart block. Increased attention should be given by the interpreter of the device's recordings to avoid false positive diagnoses that might lead to serious therapeutic actions.

Entities:  

Mesh:

Year:  2002        PMID: 12135256     DOI: 10.1053/eupc.2002.0229

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  5 in total

1.  Safe scanning, but frequent artifacts mimicking bradycardia and tachycardia during magnetic resonance imaging (MRI) in patients with an implantable loop recorder (ILR).

Authors:  J Rod Gimbel; Jamal Zarghami; Christian Machado; Bruce L Wilkoff
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-10       Impact factor: 1.468

Review 2.  [Implantable loop recorders in the diagnosis of syncope].

Authors:  B M Kaess; J R Ehrlich
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2016-12

3.  Cardiovascular Magnetic Resonance Imaging in Patients with an Implantable Loop Recorder.

Authors:  Florian Blaschke; Philipp Lacour; Thula Walter; Alexander Wutzler; Martin Huemer; Abdul Parwani; Philipp Attanasio; Leif-Hendrik Boldt; Marcus Markowski; Timm Denecke; Wilhelm Haverkamp
Journal:  Ann Noninvasive Electrocardiol       Date:  2015-12-24       Impact factor: 1.468

4.  Asystole detected by implantable loop recorders: true or false?

Authors:  Hussam Ali; Antonio Sorgente; Elisabetta Daleffe; Riccardo Cappato
Journal:  Ann Noninvasive Electrocardiol       Date:  2014-02-17       Impact factor: 1.468

5.  R-wave sensing in an implantable cardiac monitor without ECG-based preimplant mapping: results from a multicenter clinical trial.

Authors:  Andrew D Krahn; Robert A Pickett; Scott Sakaguchi; Naushad Shaik; Jian Cao; Holly S Norman; Patricia Guerrero
Journal:  Pacing Clin Electrophysiol       Date:  2013-12-02       Impact factor: 1.976

  5 in total