Twenty-four-hour ambulatory blood pressure monitoring in atrial fibrillation.

Roy Olsen1, Aina Amlie, Per Omvik.   

Abstract

BACKGROUND: Due to large beat-to-beat blood pressure variation the use of 24-h ambulatory blood pressure monitoring in patients with atrial fibrillation has been questioned.
METHODS: Repeatability and variability of 24-h ambulatory blood pressure (Accutraccer II or Diasys Integra), and daily blood pressure variation was examined in 42 patients aged 51-81 (median 73.5) years admitted for elective electrocardioversion of atrial fibrillation.
RESULTS: Before cardioversion 24-h ambulatory systolic blood pressure was slightly lower and nocturnal blood pressure reduction was larger in the group of patients who achieved sinus rhythm than in the group who maintained atrial fibrillation (11.5/10.5 versus 4.1/4.7 mmHg; P < 0.05). No statistically significant change was observed in ambulatory blood pressure after cardioversion in any of the two groups. Blood pressure variability (SD/mean) was 10-14% both in patients with and without conversion to sinus rhythm. Coefficient of repeatability (2 SD of difference) was 13.6 mmHg (16.6%) for diastolic blood pressure and 30.2 mmHg (24.7%) for systolic blood pressure in patients with normalized heart rhythm and 17.0 and 29.0 mmHg (21.5 and 22.4%) in patients with maintained atrial fibrillation, respectively.
CONCLUSION: Ambulatory blood pressure monitoring provides data with similar variability and repeatability in patients with atrial fibrillation as in subjects with normal cardiac rhythm. Twenty-four-hour ambulatory blood pressure measurement is applicable in atrial fibrillation in the same way as during sinus rhythm.

Entities:  

Mesh:

Year:  2002        PMID: 12131071     DOI: 10.1097/00126097-200206000-00002

Source DB:  PubMed          Journal:  Blood Press Monit        ISSN: 1359-5237            Impact factor:   1.444


  6 in total

1.  Association of diurnal blood pressure pattern with risk of hospitalization or death in men with heart failure.

Authors:  Jaekyu Shin; Sharoen Kline; Mariellen Moore; Yan Gong; Viralkumar Bhanderi; Carsten M Schmalfuss; Julie A Johnson; Richard S Schofield
Journal:  J Card Fail       Date:  2007-10       Impact factor: 5.712

2.  Systolic blood pressure increases in patients with atrial fibrillation regaining sinus rhythm after electrical cardioversion.

Authors:  Joakim Olbers; Ellen Jacobson; Fredrik Viberg; Nils Witt; Petter Ljungman; Mårten Rosenqvist; Jan Östergren
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-02-14       Impact factor: 3.738

3.  How does blood pressure change in hypertensive patients with atrial fibrillation after successful electrical cardioversion?

Authors:  Cesare Cuspidi; Marijana Tadic; Guido Grassi
Journal:  J Clin Hypertens (Greenwich)       Date:  2019-02-14       Impact factor: 3.738

4.  Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysis.

Authors:  Christopher E Clark; Sinead T J McDonagh; Richard J McManus
Journal:  J Hum Hypertens       Date:  2019-01-10       Impact factor: 3.012

5.  Reliability of Oscillometric Blood Pressure Monitoring in Atrial Fibrillation Patients Admitted for Electric Cardioversion.

Authors:  Monica Maselli; Valter Giantin; Domenico Corrado; Alessandro Franchin; Francesca Attanasio; Valentina Pengo; Alessandra Tramontano; Pietro De Toni; Egle Perissinotto; Enzo Manzato
Journal:  J Clin Hypertens (Greenwich)       Date:  2015-04-09       Impact factor: 3.738

6.  Effects of Early-Stage Blood Pressure Variability on the Functional Outcome in Acute Ischemic Stroke Patients With Symptomatic Intracranial Artery Stenosis or Occlusion Receiving Intravenous Thrombolysis.

Authors:  Mian-Xuan Yao; Dong-Hai Qiu; Wei-Cheng Zheng; Jiang-Hao Zhao; Han-Peng Yin; Yong-Lin Liu; Yang-Kun Chen
Journal:  Front Neurol       Date:  2022-03-08       Impact factor: 4.003

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.