| Literature DB >> 12120672 |
Abstract
The increasing number of computerised tomography (CT) procedures performed in Poland in recent years has resulted in a growing contribution of these examinations to the whole exposure of the population to ionising radiation from medical sources. (The number of CT examinations in Poland was 170,000 in 1995 and 460,000 in 1999.) An evaluation is presented of doses to patients in CT examinations performed with different types of CT unit. To evaluate the exposure to patients dose linear product (DLP) was measured using a NOMEX dosemeter with a pencil chamber (PTW, Frieburg) and the cylindrical PMMA phantoms 'head' and 'body'. CTDI values were evaluated according to current methodology as described in European Guidelines (EUR 16262). The measurements were performed for seven types of CT unit made by different companies. The CTDI values were also compared to reference levels recommended by IAEA. In conclusion it was found that the value of collective effective dose (2200 man.Sv), has increased in Poland nearly 4 times in comparison to 1995, whereas the number of CT examinations increased nearly 3 times in this period. For most of the 'controlled' CT scanners the values of CTDI in head procedures are near to or higher than the IAEA Reference Level (50 mGy); this can result from the protocols, which are chosen without a dose analysis.Entities:
Mesh:
Year: 2002 PMID: 12120672 DOI: 10.1093/oxfordjournals.rpd.a006735
Source DB: PubMed Journal: Radiat Prot Dosimetry ISSN: 0144-8420 Impact factor: 0.972