Literature DB >> 12118799

Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch.

Luis J Castro1, Joseph M Arcidi, Audrey L Fisher, Vincent A Gaudiani.   

Abstract

BACKGROUND: We routinely use aortic root enlargement (ARE) as part of one strategy to avoid prosthesis-patient mismatch in patients with relatively small aortic roots who are undergoing aortic valve replacement (AVR).
METHODS: We performed a retrospective review of 657 consecutive stented AVR patients at a single institution between 1995 to 2001. Of these, 114 (17%) patients underwent ARE. Root enlargement was selectively performed in patients at risk for prosthesis-patient mismatch, defined as calculated projected indexed effective orifice area (iEOA) less than 0.85 cm2/m2. This involved extension of the aortotomy between the left and noncoronary cusps, valve implantation, and Dacron patch closure of the aorta, thus permitting replacement with a valve size appropriate to body surface area.
RESULTS: The mean age of ARE patients was 72.5 +/- 11.0 years, with 32% aged 80 years or more. Of the patients, 61% were female and 27% had undergone previous cardiac operations. Combined procedures included coronary bypass in 57 patients and mitral repair or replacement in 24. The prevalence of mismatch was less than 3%. The ARE required an average of 19 minutes of additional aortic clamp time. The 30-day mortality was 0.9%. Logistic regression showed perfusion time to be the only independent predictor of mortality.
CONCLUSIONS: Our results show that ARE can be performed readily and with minimal added risk relative to standard AVR. We also present a preventive strategy to minimize mismatch predicted at time of operation from the reference value of effective orifice area for a given prosthesis and the patient's size. This includes use of ARE to enhance the potential benefit of AVR.

Entities:  

Mesh:

Year:  2002        PMID: 12118799     DOI: 10.1016/s0003-4975(02)03680-9

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  23 in total

Review 1.  Prosthesis-patient mismatch: definition, clinical impact, and prevention.

Authors:  P Pibarot; J G Dumesnil
Journal:  Heart       Date:  2005-10-26       Impact factor: 5.994

2.  Aortic valve replacement with a 16-mm CarboMedics valve in adult patients.

Authors:  Takeru Shimomura; Tadahito Eda; Shuichi Suzuki; Ken Miyahara; Akio Matsuura; Katsuhiko Yoshida
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2006-06

3.  Prevention of valve prosthesis--patient mismatch before aortic valve replacement: does it matter and is it feasible?

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Heart       Date:  2007-05       Impact factor: 5.994

4.  Usefulness of real-time three-dimensional echocardiography in evaluating aortic root diameters during a cardiac cycle.

Authors:  Chisato Izumi; Makoto Miyake; Shuichi Takahashi; Hidetaka Hayashi; Tadashi Miyanishi; Hayato Matsutani; Sumiyo Hashiwada; Kazuyo Kuwano; Jiro Sakamoto; Yoshihisa Nakagawa
Journal:  J Echocardiogr       Date:  2012-01-17

5.  eComment: Aortic-root enlargement procedures: an invaluable surgical technique.

Authors:  Christos Tourmousoglou; Antonis Pitsis; Nikolaos Nikoloudakis; Dimitrios Dougenis
Journal:  Interact Cardiovasc Thorac Surg       Date:  2016-06

6.  Mid-term results of small-sized St. Jude Medical Regent prosthetic valves (21 mm or less) for small aortic annulus.

Authors:  Hiroki Mizoguchi; Masayuki Sakaki; Kazushige Inoue; Takashi Iwata; Keikou Tei; Takuya Miura
Journal:  Heart Vessels       Date:  2012-11-17       Impact factor: 2.037

7.  Full-root Aortic Valve Replacement by Stentless Aortic Xenografts in Patients with Small Aortic Roots.

Authors:  Reza Tavakoli; Peiman Jamshidi; Max Gassmann
Journal:  J Vis Exp       Date:  2017-05-21       Impact factor: 1.355

8.  Aortic valve replacement with 17-mm St. Jude Medical Regent prosthetic valves for a small calcified aortic annulus in elderly patients.

Authors:  Shinichiro Taniguchi; Manabu Noguchi; Daisuke Onohara; Ryuichiro Shibata
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-10-13

Review 9.  Prosthesis-patient mismatch in aortic stenosis.

Authors:  Kentaro Honda; Yoshitaka Okamura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-10-17

Review 10.  New concepts in valvular hemodynamics: implications for diagnosis and treatment of aortic stenosis.

Authors:  Philippe Pibarot; Jean G Dumesnil
Journal:  Can J Cardiol       Date:  2007-10       Impact factor: 5.223

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.