Literature DB >> 12116353

Impact of the international program for Quality Assessment and Standardization for Immunological Measures Relevant to HIV/AIDS: QASI.

Francis Mandy1, Michèle Bergeron, Guy Houle, John Bradley, John Fahey.   

Abstract

Measurements of CD4 T-cell levels are essential for the assessment of human immunodeficiency virus (HIV) disease course, clinical staging, epidemiological studies, and decisions regarding prophylactic therapies against opportunistic infection. Until now, only in the industrialized countries was T-cell subset monitoring considered a practical option to assess disease progression. The Quality Assessment and Standardization for Immunological Measures Relevant to HIV/AIDS (QASI) program was established in 1997 to meet performance assessment for immunophenotyping laboratories in countries where such service is not available. The QASI program is provided at no cost to any laboratory in a resource-poor setting that wishes to participate. This report describes the beneficial impact of participation in the QASI program. Carefully selected commercial stabilized whole blood preparations were sent regularly to participating laboratories. Participants reported the T-cell subset values they obtained by flow cytometry. Once the aggregate mean values for the T-cell subsets were established for the shipment, a comprehensive and confidential report was sent to each laboratory. The results from five consecutive shipments were analyzed. The coefficient of variation decreased from 7.2% to 4.7% and from 14.2% to 8.8% for percent and absolute CD4 T-cell counts, respectively. With the implementation of the QASI program using commercial stabilized whole blood specimens, it is possible to reduce interlaboratory error. This study illustrates that a quality assessment program can improve the overall performance of laboratories. Reducing interlaboratory variation can enhance significantly the effectiveness of multicenter HIV vaccine or drug trial evaluation. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12116353     DOI: 10.1002/cyto.10088

Source DB:  PubMed          Journal:  Cytometry        ISSN: 0196-4763


  13 in total

1.  Affordable CD4(+)-T-cell counting by flow cytometry: CD45 gating for volumetric analysis.

Authors:  George Janossy; Ilesh V Jani; Nicholas J Bradley; Arsene Bikoue; Tim Pitfield; Debbie K Glencross
Journal:  Clin Diagn Lab Immunol       Date:  2002-09

2.  Particle focusing in staged inertial microfluidic devices for flow cytometry.

Authors:  John Oakey; Robert W Applegate; Erik Arellano; Dino Di Carlo; Steven W Graves; Mehmet Toner
Journal:  Anal Chem       Date:  2010-05-01       Impact factor: 6.986

3.  Specimen Referral Network to Rapidly Scale-Up CD4 Testing: The Hub and Spoke Model for Haiti.

Authors:  Frantz Jean Louis; Anna Janick Osborne; Viala Jean Elias; Josiane Buteau; Jacques Boncy; Angela Elong; Amber Dismer; Vikram Sasi; Jean Wysler Domercant; Daniel Lauture; S Arunmozhi Balajee; Barbara J Marston
Journal:  J AIDS Clin Res       Date:  2015-06-26

4.  VERITAS?: A time for VERIQAS™ and a new approach to training, education, and the quality assessment of CD4+ T lymphocyte counting (I).

Authors:  David Barnett; Liam Whitby; John Wong; Raul Louzao; John T Reilly; Thomas N Denny
Journal:  Cytometry B Clin Cytom       Date:  2011-10-13       Impact factor: 3.058

5.  Low CD4+ T-lymphocyte values in human immunodeficiency virus-negative adults in Botswana.

Authors:  Hermann Bussmann; C William Wester; Kereng V Masupu; Trevor Peter; Sarah M Gaolekwe; Soyeon Kim; Ann Marie Reich; Sam Ahn; Ying Wu; Ibou Thior; Max Essex; Richard Marlink
Journal:  Clin Diagn Lab Immunol       Date:  2004-09

6.  A Brief Chronicle of CD4 as a Biomarker for HIV/AIDS: A Tribute to the Memory of John L. Fahey.

Authors:  Jonathan M Kagan; Ana M Sanchez; Alan Landay; Thomas N Denny
Journal:  For Immunopathol Dis Therap       Date:  2015

Review 7.  CD4 immunophenotyping in HIV infection.

Authors:  David Barnett; Brooke Walker; Alan Landay; Thomas N Denny
Journal:  Nat Rev Microbiol       Date:  2008-11       Impact factor: 60.633

8.  Diagnostic accuracy and clinical utility of a simplified low cost method of counting CD4 cells with flow cytometry in Malawi: diagnostic accuracy study.

Authors:  Calman A MacLennan; Michael K P Liu; Sarah A White; Joep J G van Oosterhout; Felanji Simukonda; Joseph Bwanali; Michael J Moore; Eduard E Zijlstra; Mark T Drayson; Malcolm E Molyneux
Journal:  BMJ       Date:  2007-07-17

9.  QASI: A collaboration for implementation of an independent quality assessment programme in India.

Authors:  Adrienne F A Meyers; Michèle Bergeron; Madhuri Thakar; Tao Ding; Alexandre Martel; Paul Sandstrom; Bharati Mahajan; Philip Abraham; Sandhya Kabra; Namita Singh; Trevor Peter; Terry B Ball
Journal:  Afr J Lab Med       Date:  2016-10-12

10.  Field evaluation in Chad of community usage of CD4 T lymphocyte counting by alternative single-platform flow cytometry.

Authors:  Donato Koyalta; Mohammad-Ali Jenabian; Barou Djouater; Noël Djemadji-Oudjeil; Francois-Xavier Mbopi-Keou; Angélique Ndjoyi-Mbiguino; Laurent Bélec
Journal:  BMC Health Serv Res       Date:  2013-10-01       Impact factor: 2.655

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.