Literature DB >> 12113342

Effect of the mobile phase composition on the separation and detection of intact proteins by reversed-phase liquid chromatography-electrospray mass spectrometry.

M C García1, A C Hogenboom, H Zappey, H Irth.   

Abstract

Various buffers (ammonium acetate, ammonium formate, and ammonium hydrogencarbonate), acids (formic acid, acetic acid, heptafluorobutyric acid, and trifluoroacetic acid), and bases (ammonium hydroxide and morpholine) covering the range from 2 to 11.5 have been investigated for their performance in the separation of proteins by reversed-phase liquid chromatography (RPLC) and in their detection by electrospray mass spectrometry (ESI-MS). These additives were first tested for the detection of standard proteins by ESI-MS by flow-injection analysis (FIA). Those additives yielding the highest signals were employed for the separation of standard proteins by using three different reversed-phase columns: two C18 columns (4.6 mm I.D. and 2.1 mm I.D.) and one perfusion column (2 mm I.D.). The sensitivity of the LC-MS system was evaluated with the column giving the best results and with those LC eluents enabling the LC separation of the proteins and also yielding the highest MS signals. For that purpose, calibration curves were compared for both LC-MS and FIA-MS. Formic acid was the additive yielding the highest responses in FIA-MS and trifluoroacetic acid (TFA) gave the best separation and recovery of the proteins. However, problems related to poor recovery of the proteins in the column when formic acid was used and the significant signal suppression observed in MS when TFA was employed, made neither of them suitable for the sensitive detection of the proteins in LC-MS.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12113342     DOI: 10.1016/s0021-9673(02)00345-x

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  12 in total

1.  Mass-based fraction collection of crude synthetic peptides in analytical and preparative scale.

Authors:  Ralf Moritz; Nicola O'Reilly
Journal:  J Biomol Tech       Date:  2003-06

2.  High dead volume pumps: delay time reduction by short-term low-ratio split flow in LC/MS applications.

Authors:  Eduard Rogatsky; Daniel T Stein
Journal:  J Am Soc Mass Spectrom       Date:  2006-11-13       Impact factor: 3.109

3.  High-sensitivity TFA-free LC-MS for profiling histones.

Authors:  Jia You; Liwen Wang; Motoyasu Saji; Susan V Olesik; Matthew D Ringel; David M Lucas; John C Byrd; Michael A Freitas
Journal:  Proteomics       Date:  2011-08       Impact factor: 3.984

4.  Stereochemistry of Endogenous Palmitic Acid Ester of 9-Hydroxystearic Acid and Relevance of Absolute Configuration to Regulation.

Authors:  Andrew T Nelson; Matthew J Kolar; Qian Chu; Ismail Syed; Barbara B Kahn; Alan Saghatelian; Dionicio Siegel
Journal:  J Am Chem Soc       Date:  2017-03-28       Impact factor: 15.419

5.  Online coupling of reverse-phase and hydrophilic interaction liquid chromatography for protein and glycoprotein characterization.

Authors:  Maggie P Y Lam; S O Siu; Edward Lau; Xiuli Mao; H Z Sun; Philip C N Chiu; William S B Yeung; David M Cox; Ivan K Chu
Journal:  Anal Bioanal Chem       Date:  2010-07-15       Impact factor: 4.142

6.  Unambiguous determination of isobaric histone modifications by reversed-phase retention time and high-mass accuracy.

Authors:  Lanhao Yang; Shengjiang Tu; Chen Ren; Esther M M Bulloch; Chung-Lin Liao; Ming-Daw Tsai; Michael A Freitas
Journal:  Anal Biochem       Date:  2009-08-21       Impact factor: 3.365

7.  Optimization of reversed-phase peptide liquid chromatography ultraviolet mass spectrometry analyses using an automated blending methodology.

Authors:  Asish B Chakraborty; Scott J Berger
Journal:  J Biomol Tech       Date:  2005-12

8.  Salt Tolerance Enhancement of Liquid Chromatography-Matrix-Assisted Laser Desorption/Ionization-Mass Spectrometry Using Matrix Additive Methylenediphosphonic Acid.

Authors:  Yuki Ohta; Shinichi Iwamoto; Shin-Ichirou Kawabata; Ritsuko Tanimura; Koichi Tanaka
Journal:  Mass Spectrom (Tokyo)       Date:  2014-09-03

9.  Microfluidic ion stripper for removal of trifluoroacetic acid from mobile phases used in HILIC-MS of intact proteins.

Authors:  Sam Wouters; Sebastiaan Eeltink; Rob Haselberg; Govert W Somsen; Andrea F G Gargano
Journal:  Anal Bioanal Chem       Date:  2021-05-28       Impact factor: 4.142

10.  Capillary HILIC-MS: A New Tool for Sensitive Top-Down Proteomics.

Authors:  Andrea F G Gargano; Liana S Roca; Ryan T Fellers; Max Bocxe; Elena Domínguez-Vega; Govert W Somsen
Journal:  Anal Chem       Date:  2018-05-18       Impact factor: 6.986

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.