| Literature DB >> 12111963 |
Onno Wink1, Alejandro F Frangi, Bert Verdonck, Max A Viergever, Wiro J Niessen.
Abstract
A method is introduced to automatically find the coronary axis based on two or more user-defined points, even in the presence of a severe stenosis. The coronary axis is determined by finding a minimum cost path (MCP) in a feature image in which the tubular-like structures are enhanced. The results of the proposed method were compared with manually drawn central axes to estimate the accuracy. In 32 3D TFE-EPI acquisitions of patients and volunteers, 14 right coronary arteries (RCAs), 15 left anterior descending arteries (LADs), and eight left circumflex arteries (LCXs) were manually tracked twice by two operators to determine a reference axis and to assess the inter- and intra-user variability. On average, the maximum distance to the reference axis, based on only two user-defined points, is less than 1.5 mm; the average distance is around 0.65 mm, which is less than the average in-plane resolution. The results of the method are comparable to those of the manual operators. Copyright 2002 Wiley-Liss, Inc.Entities:
Mesh:
Year: 2002 PMID: 12111963 DOI: 10.1002/mrm.10164