Literature DB >> 12111940

Diffusion tensor imaging using single-shot SENSE-EPI.

Roland Bammer1, Martin Auer, Stephen L Keeling, Michael Augustin, Lara A Stables, Rupert W Prokesch, Rudolf Stollberger, Michael E Moseley, Franz Fazekas.   

Abstract

SENSitivity Encoding (SENSE) greatly enhances the quality of diffusion-weighted echo-planar imaging (EPI) by reducing blurring and off-resonance artifacts. Such improvement would also be desirable for diffusion tensor imaging (DTI), but measures derived from the diffusion tensor can be extremely sensitive to any kind of image distortion. Whether DTI is feasible in combination with SENSE has not yet been explored, and is the focus of this study. Using a SENSE-reduction factor of 2, DTI scans in eight healthy volunteers were carried out with regular- and high-resolution acquisition matrices. To further improve the stability of the SENSE reconstruction, a new coil-sensitivity estimation technique based on variational calculus and the principles of matrix regularization was applied. With SENSE, maps of the trace of the diffusion tensor and of fractional anisotropy (FA) had improved spatial resolution and less geometric distortion. Overall, the geometric distortions were substantially removed and a significant resolution enhancement was achieved with almost the same scan time as regular EPI. DTI was even possible without the use of quadrature body coil (QBC) reference scans. Geometry-factor-related noise enhancement was only discernible in maps generated with higher-resolution matrices. Error boundaries for residual fluctuations in SENSE reconstructions are discussed. Our results suggest that SENSE can be combined with DTI and may present an important adjunct for future neuroimaging applications of this technique. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2002        PMID: 12111940     DOI: 10.1002/mrm.10184

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  73 in total

1.  Sensitivity-encoded diffusion tensor MR imaging of the cervical cord.

Authors:  Mara Cercignani; Mark A Horsfield; Federica Agosta; Massimo Filippi
Journal:  AJNR Am J Neuroradiol       Date:  2003 Jun-Jul       Impact factor: 3.825

Review 2.  Diffusion tensor imaging of the brain: review of clinical applications.

Authors:  P C Sundgren; Q Dong; D Gómez-Hassan; S K Mukherji; P Maly; R Welsh
Journal:  Neuroradiology       Date:  2004-04-21       Impact factor: 2.804

3.  Comparison of single-shot echo-planar and line scan protocols for diffusion tensor imaging.

Authors:  Marek Kubicki; Stephan E Maier; Carl-Frederik Westin; Hatsuho Mamata; Hal Ersner-Hershfield; Raul Estepar; Ron Kikinis; Ferenc A Jolesz; Robert W McCarley; Martha E Shenton
Journal:  Acad Radiol       Date:  2004-02       Impact factor: 3.173

4.  High-resolution diffusion tensor imaging of the brain stem at 3 T.

Authors:  Lidia M Nagae-Poetscher; Hangyi Jiang; Setsu Wakana; Xavier Golay; Peter C M van Zijl; Susumu Mori
Journal:  AJNR Am J Neuroradiol       Date:  2004-09       Impact factor: 3.825

5.  Corticospinal tractography with morphological, functional and diffusion tensor MRI: a comparative study of four deterministic algorithms used in clinical routine.

Authors:  Romuald Seizeur; Nicolas Wiest-Daessle; Sylvain Prima; Camille Maumet; Jean-Christophe Ferre; Xavier Morandi
Journal:  Surg Radiol Anat       Date:  2012-03-18       Impact factor: 1.246

6.  Lognormal Distributions and Geometric Averages of Symmetric Positive Definite Matrices.

Authors:  Armin Schwartzman
Journal:  Int Stat Rev       Date:  2015-08-28       Impact factor: 2.217

7.  Informed RESTORE: A method for robust estimation of diffusion tensor from low redundancy datasets in the presence of physiological noise artifacts.

Authors:  Lin-Ching Chang; Lindsay Walker; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2012-01-27       Impact factor: 4.668

8.  High-resolution human diffusion tensor imaging using 2-D navigated multishot SENSE EPI at 7 T.

Authors:  Ha-Kyu Jeong; John C Gore; Adam W Anderson
Journal:  Magn Reson Med       Date:  2012-05-16       Impact factor: 4.668

9.  Assessment of tumor morphology on diffusion-weighted (DWI) breast MRI: Diagnostic value of reduced field of view DWI.

Authors:  Maarten W Barentsz; Valentina Taviani; Jung M Chang; Debra M Ikeda; Kanae K Miyake; Suchandrima Banerjee; Maurice A A J van den Bosch; Brian A Hargreaves; Bruce L Daniel
Journal:  J Magn Reson Imaging       Date:  2015-04-24       Impact factor: 4.813

10.  Diffusion-weighted radial fast spin-echo for high-resolution diffusion tensor imaging at 3T.

Authors:  Joelle E Sarlls; Carlo Pierpaoli
Journal:  Magn Reson Med       Date:  2008-08       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.