Literature DB >> 12101478

[Multislice helical CT (MSCT) for mid-facial trauma: Optimization of parameters for scanning and reconstruction].

S Dammert1, M Funke, H A Merten, S Obernauer, E Grabbe.   

Abstract

PURPOSE: To determine the optimal scan parameters in multislice helical CT (MSCT) of the facial bone complex for both axial scanning and multiplanar reconstructions.
MATERIAL AND METHODS: An anthropomorphic skull phantom was examined with a MSCT. Axial scans were performed with continuously increasing collimations (4 x 1.25 - 4 x 2.5 mm), tube current (20 - 200 mA) and table speeds (3.75 mm/rot. and 7.5 mm/rot.). Multiplanar reconstructions in coronal and parasagittal planes with different reconstruction increment and slice thickness were evaluated in terms of image noise, contour artifacts and visualisation of anatomical structures.
RESULTS: The best image quality was obtained with a collimation of 4 x 1.25 mm and a table speed of 3.75 mm/rot. A reconstruction increment of 0.6 mm achieved the best time to image quality relation. With these parameters the bone structures were depicted in an optimal way without artifacts. The tube current could be reduced to 50 mA without significant loss of image quality. The optimized protocol was used for regular routine examinations in patients with facial trauma (n = 66).
CONCLUSIONS: Low-dose MSCT using thin collimation, low table speed and small reconstruction increments provides excellent data for both axial images and multiplanar reconstructions in patients with facial trauma. An additional examination in coronal orientation is therefore no longer necessary.

Entities:  

Mesh:

Year:  2002        PMID: 12101478     DOI: 10.1055/s-2002-32682

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  4 in total

Review 1.  [Fair in the face: modern diagnostics of midfacial trauma].

Authors:  J E W Zajaczek; T Rodt; M Keberle
Journal:  Radiologe       Date:  2007-07       Impact factor: 0.635

2.  Comparison of whole-body 64-slice multidetector computed tomography and conventional radiography in staging of multiple myeloma.

Authors:  Patric Kröpil; Roland Fenk; Lars B Fritz; Dirk Blondin; Guido Kobbe; Ulrich Mödder; Mathias Cohnen
Journal:  Eur Radiol       Date:  2007-10-09       Impact factor: 5.315

3.  Radiation dose reduction in multidetector CT in fracture evaluation.

Authors:  Jung Woo Yi; Hee Jin Park; So Yeon Lee; Myung Ho Rho; Hyun Pyo Hong; Yoon Jung Choi; Mi Sung Kim
Journal:  Br J Radiol       Date:  2017-07-14       Impact factor: 3.039

4.  Evaluation of ultra-low dose CT in the diagnosis of pediatric-like fractures using an experimental animal study.

Authors:  Joerg D Moritz; Beata Hoffmann; Dirk Sehr; Katrin Keil; Juliane Eggerking; Godo Groth; Amke Caliebe; Jens Dischinger; Martin Heller; Hendrik Bolte
Journal:  Korean J Radiol       Date:  2012-03-07       Impact factor: 3.500

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.