Literature DB >> 12100813

Echogenic bowel in intrauterine growth restriction fetuses: does this jeopardize the gut?

Reuwen Achiron1, Rami Mazkereth, Raoul Orvieto, Jacob Kuint, Shlomo Lipitz, Zeev Rotstein.   

Abstract

OBJECTIVE: To investigate the association between intrauterine growth restriction (IUGR) fetuses with echogenic bowel and high resistance in the umbilical artery and increased risk of developing neonatal necrotizing enterocolitis.
METHODS: We analyzed two groups: group 1, singleton IUGR fetuses with echogenic bowel or reversed diastolic flow in the umbilical artery, and group 2, neonates who were diagnosed as having neonatal necrotizing enterocolitis. In group 1, the pulsatility index of the superior mesenteric artery and celiac trunk were determined. In group 2, a retrospective analysis was carried out from the medical records of the neonates.
RESULTS: Fifteen fetuses with echogenic bowel and severe IUGR were evaluated by Doppler studies, and 21 neonates with neonatal necrotizing enterocolitis were reviewed. In group 1, none of the IUGR fetuses developed neonatal necrotizing enterocolitis, whereas in group 2, only one neonate was defined as IUGR. The mean gestational age at delivery did not differ statistically between the two groups (28.8 +/- 2.3 weeks versus 30.1 +/- 3.3 weeks), whereas the mean birth weight was significantly lower in the first group (700 +/- 200 g versus 1431 +/- 466 g in the second group, P <.001). The mean pulsatility index +/- standard deviation in the superior mesenteric artery and celiac trunk of the IUGR fetuses were 1.5 +/- 0.14 and 1.2 +/- 0.17, respectively, both being found significantly lower than those of normal, appropriate controls (1.9 +/- 0.15 and 1.7 +/- 0.1, respectively, P <.005).
CONCLUSION: Fetal echogenic bowel in IUGR fetuses is not associated with development of neonatal necrotizing enterocolitis. In these fetuses, vasodilatation in the superior mesenteric artery and celiac trunk have been demonstrated.

Entities:  

Mesh:

Year:  2002        PMID: 12100813     DOI: 10.1016/s0029-7844(02)02038-0

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  2 in total

1.  Echogenic bowel on second-trimester ultrasonography: evaluating the risk of adverse pregnancy outcome.

Authors:  Katherine R Goetzinger; Alison G Cahill; George A Macones; Anthony O Odibo
Journal:  Obstet Gynecol       Date:  2011-06       Impact factor: 7.661

2.  Blood flow parameters of the superior mesenteric artery as an early predictor of intestinal dysmotility in preterm infants.

Authors:  Eva Robel-Tillig; Matthias Knüpfer; Ferdinand Pulzer; Christoph Vogtmann
Journal:  Pediatr Radiol       Date:  2004-09-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.