First clinical use of a novel bioartificial liver support system (BLSS).

George V Mazariegos1, John F Patzer, Roberto C Lopez, Mauricio Giraldo, Michael E Devera, Tracy A Grogan, Yue Zhu, Melissa L Fulmer, Bruce P Amiot, David J Kramer.   

Abstract

The first clinical use of the Excorp Medical Bioartificial Liver Support System (BLSS) in support of a 41-year-old African-American female with fulminant hepatic failure is described. The BLSS is currently in a Phase I/II safety evaluation at the University of Pittsburgh/UPMC System. Inclusion criteria for the study are patients with acute liver failure, any etiology, presenting with encephalopathy deteriorating beyond Parson's Grade 2. The BLSS consists of a blood pump; a heat exchanger to control blood temperature; an oxygenator to control oxygenation and pH; a bioreactor; and associated pressure and flow alarm systems. Patient liver support is provided by 70-100 g of porcine liver cells housed in the hollow fiber bioreactor. The patient exhibited transient hypotension and thrombocytopenia at initiation of perfusion. The only unanticipated safety event was a lowering of patient glucose level at the onset of perfusion with the BLSS that was treatable with intravenous glucose administration. Moderate changes in blood biochemistries pre- and post perfusion are indicative of liver support being provided by the BLSS. While the initial experience with the BLSS is encouraging, completion of the Phase I/II study is required in order to more fully understand the safety aspects of the BLSS.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12096789     DOI: 10.1034/j.1600-6143.2002.20311.x

Source DB:  PubMed          Journal:  Am J Transplant        ISSN: 1600-6135            Impact factor:   8.086


  14 in total

Review 1.  [Liver replacement therapy. Reliable indications in acute liver failure].

Authors:  K Rifai; M Ott; M M Bahr; A Schneider; M P Manns
Journal:  Internist (Berl)       Date:  2003-12       Impact factor: 0.743

Review 2.  Artificial and bioartificial liver support: a review of perfusion treatment for hepatic failure patients.

Authors:  Katsutoshi Naruse; Wei Tang; Masatoshi Makuuch
Journal:  World J Gastroenterol       Date:  2007-03-14       Impact factor: 5.742

3.  Cell therapeutic options in liver diseases: cell types, medical devices and regulatory issues.

Authors:  Andreas K Nussler; Katrin Zeilinger; Lilianna Schyschka; Sabrina Ehnert; Jörg C Gerlach; Xueying Yan; Serene M L Lee; Maren Ilowski; Wolfgang E Thasler; Thomas S Weiss
Journal:  J Mater Sci Mater Med       Date:  2011-04-03       Impact factor: 3.896

Review 4.  Acute kidney injury in the ICU: from injury to recovery: reports from the 5th Paris International Conference.

Authors:  Rinaldo Bellomo; Claudio Ronco; Ravindra L Mehta; Pierre Asfar; Julie Boisramé-Helms; Michael Darmon; Jean-Luc Diehl; Jacques Duranteau; Eric A J Hoste; Joannes-Boyau Olivier; Matthieu Legrand; Nicolas Lerolle; Manu L N G Malbrain; Johan Mårtensson; Heleen M Oudemans-van Straaten; Jean-Jacques Parienti; Didier Payen; Sophie Perinel; Esther Peters; Peter Pickkers; Eric Rondeau; Miet Schetz; Christophe Vinsonneau; Julia Wendon; Ling Zhang; Pierre-François Laterre
Journal:  Ann Intensive Care       Date:  2017-05-04       Impact factor: 6.925

5.  Development and perspectives of perfusion treatment for liver failure.

Authors:  Katsutoshi Naruse; Hiroshi Nagashima; Yasuyuki Sakai; Norihiro Kokudo; Masatoshi Makuuchi
Journal:  Surg Today       Date:  2005       Impact factor: 2.549

6.  Systematic review: extracorporeal bio-artificial liver-support system for liver failure.

Authors:  Jinyang Gu; Xiaolei Shi; Haozhen Ren; Qingxiang Xu; Jun Wang; Jiangqiang Xiao; Yitao Ding
Journal:  Hepatol Int       Date:  2012-03-28       Impact factor: 6.047

7.  Pharmacokinetic considerations in development of a bioartificial liver.

Authors:  Hiroo Iwata; Yuichiro Ueda
Journal:  Clin Pharmacokinet       Date:  2004       Impact factor: 6.447

Review 8.  [Acute liver failure].

Authors:  K Rifai; M J Bahr
Journal:  Internist (Berl)       Date:  2003-05       Impact factor: 0.743

9.  Bifunctional polyethersulfone hollow fiber with a porous, single-layer skin for use as a bioartificial liver bioreactor.

Authors:  Shichang Zhang; Tao Liu; Li Chen; Mingliang Ren; Bo Zhang; Zhengguo Wang; Yingjie Wang
Journal:  J Mater Sci Mater Med       Date:  2012-05-15       Impact factor: 3.896

10.  Similarities in the immunoglobulin response and VH gene usage in rhesus monkeys and humans exposed to porcine hepatocytes.

Authors:  Joanne L Zahorsky-Reeves; Clare R Gregory; Donald V Cramer; Insiyyah Y Patanwala; Andrew E Kyles; Dominic C Borie; Mary K Kearns-Jonker
Journal:  BMC Immunol       Date:  2006-03-20       Impact factor: 3.615

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.