Literature DB >> 15005636

Pharmacokinetic considerations in development of a bioartificial liver.

Hiroo Iwata1, Yuichiro Ueda.   

Abstract

We consider the pharmacokinetics of bioartificial livers (BALs) prepared using a hollow fibre module with respect to two key functions, detoxification and plasma protein supply, and present the results in a simple form. We then discuss the advantages and disadvantages of BAL therapy in comparison with the non-biological therapies of haemodialysis and plasma exchange. Nitrogenous and other potentially toxic compounds, such as ammonia, mercaptans, short-chain fatty acids and gamma-aminobutyric acid, are produced in the bowels and accumulate in the systemic blood because of impaired elimination by the ailing liver. Adrenal and gonadal steroids, including corticosteroids, estrogens, progestins and androgens, are biosynthesised, and high concentrations of these hormones become harmful. All these endogenously produced toxins require effective metabolism. In haemodialysis, toxins that permeate through the hollow fibre membrane are rapidly removed by the dialysate flow, and their concentrations decrease to almost zero. In a BAL bioreactor, the toxins are slowly metabolised by hepatocytes in the hollow fibres, and decreased to concentrations that are inversely proportional to the number of hepatocytes in the BAL, even after a long-term assist. It is difficult to rationalise the clinical usage of BAL systems containing small amounts of hepatocytes (70-100g) to remove the toxins. Concentrations of plasma proteins in a patient after long-term BAL treatment are proportional to the number of hepatocytes in the device. BAL reactors prepared using porcine hepatocytes supply porcine proteins, not human proteins, to the recipient. Plasma exchange increases protein concentrations much more effectively than BAL as long as a sufficient amount of plasma is available. The blood inflow rate to the liver is about 1500 mL/min in a normal adult. On the other hand, blood draw rates to a BAL system are restricted to the range of 100-300 mL/min. Toxins that are rapidly cleared by the liver (for example, the ammonia clearance of the normal human liver is several hundred mL/min) cannot be effectively eliminated from the systemic blood by BAL systems currently under clinical evaluation. Hepatocytes are the only elements in a BAL reactor that can metabolise toxins and synthesise proteins, and thus BAL performance increases with the increasing number of hepatocytes in the bioreactor. The human liver weighs about 1500 g and contains about 80% hepatocytes, i.e. about 1200 g of hepatocytes. The blood flow through the liver is about 1500 mL/min in a normal adult. To effectively replace liver functions would require a BAL reactor containing the functional equivalent of several hundreds of grams of human hepatocytes with an extracorporeal perfusion rate of more than 1000 mL/min. At this point, only orthotopic liver transplantation can meet these criteria.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15005636     DOI: 10.2165/00003088-200443040-00001

Source DB:  PubMed          Journal:  Clin Pharmacokinet        ISSN: 0312-5963            Impact factor:   6.447


  15 in total

1.  What progress with artificial livers?

Authors:  P C Hayes; A Lee
Journal:  Lancet       Date:  2001-10-20       Impact factor: 79.321

Review 2.  Advances in bioartificial liver devices.

Authors:  J W Allen; T Hassanein; S N Bhatia
Journal:  Hepatology       Date:  2001-09       Impact factor: 17.425

3.  Plasma versus whole blood perfusion in a bioartificial liver assist device.

Authors:  John F Patzer; Brian Campbell; Richard Miller
Journal:  ASAIO J       Date:  2002 May-Jun       Impact factor: 2.872

4.  System design of a bioartificial liver with a high performance hemodialyzer as an immunoisolator using a mathematical kinetic model.

Authors:  T Kanamori; K Yanagi; T Sato; T Shinbo; N Ohshima
Journal:  Int J Artif Organs       Date:  2003-04       Impact factor: 1.595

5.  Bioreactor for a larger scale hepatocyte in vitro perfusion.

Authors:  J C Gerlach; J Encke; O Hole; C Müller; C J Ryan; P Neuhaus
Journal:  Transplantation       Date:  1994-11-15       Impact factor: 4.939

6.  In vitro evaluation of metabolic functions of a bioartificial liver.

Authors:  H Iwata; T Sajiki; H Maeda; Y G Park; B Zhu; S Satoh; T Uesugi; I Ikai; Y Yamaoka; Y Ikada
Journal:  ASAIO J       Date:  1999 Jul-Aug       Impact factor: 2.872

7.  Adult-to-adult living donor liver transplantation using extended right lobe grafts.

Authors:  C M Lo; S T Fan; C L Liu; W I Wei; R J Lo; C L Lai; J K Chan; I O Ng; A Fung; J Wong
Journal:  Ann Surg       Date:  1997-09       Impact factor: 12.969

8.  Extracorporeal application of a gel-entrapment, bioartificial liver: demonstration of drug metabolism and other biochemical functions.

Authors:  S L Nyberg; K Shirabe; M V Peshwa; T D Sielaff; P L Crotty; H J Mann; R P Remmel; W D Payne; W S Hu; F B Cerra
Journal:  Cell Transplant       Date:  1993 Nov-Dec       Impact factor: 4.064

9.  Pharmacokinetic analysis verifies P450 function during in vitro and in vivo application of a bioartificial liver.

Authors:  S L Nyberg; H J Mann; R P Remmel; W S Hu; F B Cerra
Journal:  ASAIO J       Date:  1993 Jul-Sep       Impact factor: 2.872

Review 10.  Extracorporeal liver support. Application to fulminant hepatic failure.

Authors:  N L Sussman; G T Gislason; J H Kelly
Journal:  J Clin Gastroenterol       Date:  1994-06       Impact factor: 3.062

View more
  4 in total

1.  Artificial and bioartificial liver support.

Authors:  Gesine Pless
Journal:  Organogenesis       Date:  2007-01       Impact factor: 2.500

2.  Efficient One-Step Production of Microencapsulated Hepatocyte Spheroids with Enhanced Functions.

Authors:  Hon Fai Chan; Ying Zhang; Kam W Leong
Journal:  Small       Date:  2016-04-01       Impact factor: 13.281

Review 3.  Cell sources, liver support systems and liver tissue engineering: alternatives to liver transplantation.

Authors:  Soo Young Lee; Han Joon Kim; Dongho Choi
Journal:  Int J Stem Cells       Date:  2015-05       Impact factor: 2.500

4.  Toward angiogenesis of implanted bio-artificial liver using scaffolds with type I collagen and adipose tissue-derived stem cells.

Authors:  Jae Geun Lee; Seon Young Bak; Ji Hae Nahm; Sang Woo Lee; Seon Ok Min; Kyung Sik Kim
Journal:  Korean J Hepatobiliary Pancreat Surg       Date:  2015-05-31
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.