Literature DB >> 12095572

Electron conformal radiotherapy using bolus and intensity modulation.

Rajat J Kudchadker1, Kenneth R Hogstrom, Adam S Garden, Marsha D McNeese, Robert A Boyd, John A Antolak.   

Abstract

PURPOSE: Conformal electron beam therapy can be delivered using shaped bolus, which varies the penetration of the electrons across the incident beam so that the 90% isodose surface conforms to the distal surface of the planning target volume (PTV). Previous use of this modality has shown that the irregular proximal surface of the bolus causes the dose heterogeneity in the PTV to increase from 10%, the typical dose spread of a flat-water surface to approximately 20%. The present work evaluates the ability to restore dose homogeneity by varying the incident electron intensity. METHODS AND MATERIALS: Three patients, one each with chest wall, thorax, and head-and-neck cancer, were planned using electron conformal therapy with bolus, with and without intensity modulation. Resulting dose distributions and dose-volume histograms were compared with non-intensity-modulated bolus plans.
RESULTS: In all cases, the DeltaD(90%-10%) for the PTV was reduced; for example, for the head-and-neck case, the DeltaD(90%-10%) for the PTV was reduced from 14.9% to 9.2%. This reduction in dose spread is a direct result of intensity modulation.
CONCLUSIONS: The results showed that intensity-modulated electron beams could significantly improve the dose homogeneity in the PTV for patients treated with electron conformal therapy using shaped bolus.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12095572     DOI: 10.1016/s0360-3016(02)02811-0

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  16 in total

1.  Preliminary comparison of helical tomotherapy and mixed beams of unmodulated electrons and intensity modulated radiation therapy for treating superficial cancers of the parotid gland and nasal cavity.

Authors:  Olivier Blasi; Jonas D Fontenot; Robert S Fields; John P Gibbons; Kenneth R Hogstrom
Journal:  Radiat Oncol       Date:  2011-12-28       Impact factor: 3.481

2.  Electron modulated arc therapy (EMAT) using photon MLC for postmastectomy chest wall treatment I: Monte Carlo-based dosimetric characterizations.

Authors:  Chaoqiong Ma; David Parsons; Mingli Chen; Steve Jiang; Qing Hou; Xuejun Gu; Weiguo Lu
Journal:  Phys Med       Date:  2019-10-10       Impact factor: 2.685

3.  Measurement and modeling of out-of-field doses from various advanced post-mastectomy radiotherapy techniques.

Authors:  Jihyung Yoon; David Heins; Xiaodong Zhao; Mary Sanders; Rui Zhang
Journal:  Phys Med Biol       Date:  2017-11-13       Impact factor: 3.609

4.  Evaluation of a mixed beam therapy for postmastectomy breast cancer patients: Bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy.

Authors:  Rui Zhang; David Heins; Mary Sanders; Beibei Guo; Kenneth Hogstrom
Journal:  Med Phys       Date:  2018-05-27       Impact factor: 4.071

5.  Evaluation of various boluses in dose distribution for electron therapy of the chest wall with an inward defect.

Authors:  Hoda Mahdavi; Keyvan Jabbari; Mahnaz Roayaei
Journal:  J Med Phys       Date:  2016 Jan-Mar

6.  Introduction to passive electron intensity modulation.

Authors:  Kenneth R Hogstrom; Robert L Carver; Erin L Chambers; Kevin Erhart
Journal:  J Appl Clin Med Phys       Date:  2017-09-06       Impact factor: 2.102

7.  Utilization of a 3D printer to fabricate boluses used for electron therapy of skin lesions of the eye canthi.

Authors:  Magdalena Łukowiak; Karolina Jezierska; Marek Boehlke; Marzena Więcko; Adam Łukowiak; Wojciech Podraza; Mirosław Lewocki; Bartłomiej Masojć; Michał Falco
Journal:  J Appl Clin Med Phys       Date:  2016-11-30       Impact factor: 2.102

8.  Use of 3D printers to create a patient-specific 3D bolus for external beam therapy.

Authors:  Sarah Burleson; Jamie Baker; An Ting Hsia; Zhigang Xu
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

9.  Dosimetric characteristics of an electron multileaf collimator for modulated electron radiation therapy.

Authors:  Ahmed Abdel Rahman Eldib; Mohamed I ElGohary; Jiajin Fan; Lihui Jin; Jinsheng Li; Charlie Ma; Nader A Elsherbini
Journal:  J Appl Clin Med Phys       Date:  2010-04-12       Impact factor: 2.102

10.  Utilization of custom electron bolus in head and neck radiotherapy.

Authors:  R J Kudchadker; J A Antolak; W H Morrison; P F Wong; K R Hogstrom
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

View more