Literature DB >> 12091673

Detection of lung cancer on chest radiographs: analysis on the basis of size and extent of ground-glass opacity at thin-section CT.

Mitsuko Tsubamoto1, Keiko Kuriyama, Shoji Kido, Jun Arisawa, Nobuaki Kohno, Takeshi Johkoh, Noriyuki Tomiyama, Osamu Honda, Chikazumi Kuroda.   

Abstract

PURPOSE: To evaluate the detection of small peripheral lung tumors on chest radiographs on the basis of the size of the tumor and its extent of ground-glass opacity (GGO) at thin-section computed tomography (CT).
MATERIALS AND METHODS: Chest radiographs of 75 patients with peripheral carcinomas 20 mm in diameter or smaller (26 localized bronchioloalveolar carcinomas [BACs], 49 other carcinomas) and 60 normal chest radiographs were retrospectively reviewed individually by 10 radiologists. The extent of GGO within the lesions at thin-section CT was reviewed retrospectively. The detection rates for localized BAC and other carcinomas on chest radiographs were calculated and were correlated with tumor size and extent of GGO.
RESULTS: The mean sensitivity for detection of small peripheral carcinomas was 58.5% +/- 8.8 (standard error) for localized BAC and was 78.6% +/- 5.1 for other carcinomas (P =.024). Lesions that were smaller than 15 mm in diameter and had an extent of GGO of 70% or greater at thin-section CT were more difficult to detect than tumors that had larger diameters or less extensive GGO (chi(2) = 8.13, df = 1, P =.004).
CONCLUSION: The detection of small peripheral carcinomas on chest radiographs is influenced by tumor size and extent of GGO as seen at thin-section CT.

Entities:  

Mesh:

Year:  2002        PMID: 12091673     DOI: 10.1148/radiol.2241001445

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  7 in total

1.  Multidetector CT features of pulmonary focal ground-glass opacity: differences between benign and malignant.

Authors:  L Fan; S-Y Liu; Q-C Li; H Yu; X-S Xiao
Journal:  Br J Radiol       Date:  2011-11-29       Impact factor: 3.039

2.  Effects of dual-energy subtraction chest radiography on detection of small pulmonary nodules with varying attenuation: receiver operating characteristic analysis using a phantom study.

Authors:  Seitaro Oda; Kazuo Awai; Yoshinori Funama; Daisuke Utsunomiya; Yumi Yanaga; Koichi Kawanaka; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2010-05-01       Impact factor: 2.374

3.  Solitary pure ground-glass nodules measuring 5 mm or less: current imaging management, question and suggestion.

Authors:  Li Fan; Shi-Yuan Liu
Journal:  J Thorac Dis       Date:  2015-08       Impact factor: 2.895

4.  Low-dose CT screening in an Asian population with diverse risk for lung cancer: A retrospective cohort study.

Authors:  Chin A Yi; Kyung Soo Lee; Myung-Hee Shin; Yun Yung Cho; Yoon-Ho Choi; O Jung Kwon; Kyung Eun Shin
Journal:  Eur Radiol       Date:  2015-02-14       Impact factor: 5.315

5.  Correlation between glucose transporter-1 expression and 18F-fluoro-2-deoxyglucose uptake on positron emission tomography in lung cancer.

Authors:  Katsuo Usuda; Motoyasu Sagawa; Hirokazu Aikawa; Masakatsu Ueno; Makoto Tanaka; Yuichiro Machida; Xi-Tong Zhao; Yoshimichi Ueda; Koutaro Higashi; Tsutomu Sakuma
Journal:  Gen Thorac Cardiovasc Surg       Date:  2010-08-12

6.  Detection of lung cancer using single-exposure dual-energy subtraction chest radiography.

Authors:  Kana Ide; Hiroshi Mogami; Tadashi Murakami; Yoshifumi Yasuhara; Masao Miyagawa; Teruhito Mochizuki
Journal:  Radiat Med       Date:  2007-06-27

Review 7.  Small peripheral lung adenocarcinoma: CT and histopathologic characteristics and prognostic implications.

Authors:  Zhi-gang Chu; Zhi-gang Yang; Heng Shao; Zhi-yu Zhu; Wen Deng; Shi-si Tang; Jing Chen; Yuan Li
Journal:  Cancer Imaging       Date:  2011-12-28       Impact factor: 3.909

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.