The quotient end-tidal/inspired concentration of sevoflurane in a low-flow system.

Anders Johansson1, Dag Lundberg, Hans Henrik Luttropp.   

Abstract

STUDY
OBJECTIVE: To investigate the effect of two different fresh gas flows on inspired and end-tidal sevoflurane concentration for a given vaporizer setting in a low-flow anesthesia system.
DESIGN: Prospective clinical study.
SETTING: Department of Anesthesiology of a university teaching hospital. PATIENTS: 56 ASA physical status I and II patients without systemic diseases, having elective surgery with an expected anesthesia time of at least 120 minutes.
INTERVENTIONS: Patients were randomly assigned to receive either 1.0 or 2.0 L/min fresh gas flow with the vaporizer setting fixed at 2% sevoflurane. The inspired (In), end-tidal (Et), and Et/In ratio sevoflurane concentrations were estimated.
MEASUREMENTS AND MAIN RESULTS: After 120 minutes of sevoflurane anesthesia the inspired and end-tidal sevoflurane concentration were 1.45 +/- 0.10% versus 1.28 +/- 0.12% (p < 0.001) in the 1.0 L/min group and 1.64 +/- 0.08% versus 1.46 +/- 0.11% (p < 0.001) in the 2.0 L/min group. The ratio end-tidal and inspired concentrations/vaporizer setting was 0.64 +/- 0.06 and 0.73 +/- 0.05 in the 1.0 L/min group versus 0.73 +/- 0.05 and 0.82 +/- 0.04 in the 2.0 L/min group. For the ratio inspired and end-tidal/vaporizer setting there were significant difference between the groups (p < 0.001). The estimated ratio end-tidal/inspired was 0.88 +/- 0.04 in the 1.0 L/min group versus 0.89 +/- 0.04 in the 2.0 L/min group (ns).
CONCLUSION: After 120 minutes of sevoflurane anesthesia at a vaporizer setting of 2% there is a significant difference between fresh gas flow of 1.0 and 2.0 L/min for inspired and end-tidal concentrations, but not for the ratio end-tidal/inspired.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12088809     DOI: 10.1016/s0952-8180(02)00358-6

Source DB:  PubMed          Journal:  J Clin Anesth        ISSN: 0952-8180            Impact factor:   9.452


  2 in total

1.  Site of fresh gas inlet and ratios of the delivered fraction and inspired fraction of inhaled isoflurane and sevoflurane in low-flow anesthesia.

Authors:  Taeko Fukuda; Atsuo Fukunaga; Hidenori Toyooka
Journal:  J Anesth       Date:  2006       Impact factor: 2.078

2.  A randomised prospective comparison of equilibration point and changing gas composition during low-flow anaesthesia with sevoflurane vs desflurane.

Authors:  Pratibha Toal; Sheetal Chiplonkar; Pratik Panchal
Journal:  Indian J Anaesth       Date:  2019-10-10
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.