Literature DB >> 12088392

Bacterial and fungal aerosols in indoor environment in Central and Eastern European countries.

Rafał L Górny1, Jacek Dutkiewicz.   

Abstract

Studies of indoor bioaerosols conducted in Central and Eastern European countries, as a result of the scarcity of funding, mostly do not attain the level presented by similar studies in Northern America and Western Europe. For socio-economic reasons, most of the intense studies on indoor bioaerosols in Central and Eastern European countries were carried out in industrial facilities and have contributed significantly to occupational health science. In contrast, until recently, insufficient of studies have been conducted on bioaerosols of residential and communal premises (dwellings, offices, schools, etc.) and no network for monitoring the microbiological quality of air in such premises exists. In Poland, in the mid-1990s complex bioaerosol investigations were carried out by the Bioaerosol Group at the Institute of Occupational Medicine and Environmental Health in Sosnowiec. The concentrations of airborne bacteria and fungi in dwellings without mold problems were between 88-4297 cfu/m(3) and 0-1997 cfu/m(3), while in moldy homes they were 178-4751 cfu/m(3) and 49-16,968 cfu/m(3), respectively. As many as 167 microbial species were isolated from the air of examined dwellings. Most frequently occurred Gram-positive cocci (Micrococcus/ Kocuria spp., Staphylococcus spp.), endospore-forming bacilli (Bacillus spp.), Gram-negative bacteria (Pseudomonadaceae, Aeromonas spp.), filamentous fungi (Penicillium spp., Aspergillus spp.), and yeasts. Notable studies of indoor bioaerosols have also been performed in the other Central and Eastern European countries: Lithuania, Latvia, Estonia, Russian Federation, Ukraine, Czech Republic, Slovakia, Bulgaria and Hungary, are reviewed in this article. The lack of reference limit values for bioaerosols seriously hinders interpretation of results obtained in various countries. The following residential limit values (RLV) for dwellings and communal premises are proposed for the concentration of airborne bacteria, fungi and bacterial endotoxin: 5 x 10(3) cfu/m(3), 5 x 10(3) cfu/m(3) and 5 ng/m(3) (50 EU), respectively. The proposed values of occupational exposure limit (OEL) for industrial settings contaminated by organic dust are 100 x (3) cfu/m(3), 50 x (3) cfu/m(3) and 200 ng/m(3) (2000 EU), respectively. It is also proposed that the presence in indoor air of microorganisms from risk groups 3 and 4 of European Community Directive 2000/54/EC (e.g., Mycobacterium tuberculosis, Bacillus anthracis, Coxiella burnetii), independently of the concentration, should always be inadmissible and result in preventive actions.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12088392

Source DB:  PubMed          Journal:  Ann Agric Environ Med        ISSN: 1232-1966            Impact factor:   1.447


  38 in total

1.  The statistical investigation on airborne fungi and pollen grains of atmosphere in Izmir-Turkey.

Authors:  H Boyacioglu; A Haliki; M Ates; A Guvensen; O Abaci
Journal:  Environ Monit Assess       Date:  2007-03-15       Impact factor: 2.513

2.  A study of air microbe levels in different areas of a hospital.

Authors:  Ginés Ortiz; Genoveva Yagüe; Manuel Segovia; Vicente Catalán
Journal:  Curr Microbiol       Date:  2009-03-28       Impact factor: 2.188

3.  Evaluation of the airborne bacterial population in the periodically confined Antarctic base Concordia.

Authors:  Rob Van Houdt; Patrick De Boever; Ilse Coninx; Claire Le Calvez; Roberto Dicasillati; Jacques Mahillon; Max Mergeay; Natalie Leys
Journal:  Microb Ecol       Date:  2008-10-30       Impact factor: 4.552

4.  UVC LED Irradiation Effectively Inactivates Aerosolized Viruses, Bacteria, and Fungi in a Chamber-Type Air Disinfection System.

Authors:  Do-Kyun Kim; Dong-Hyun Kang
Journal:  Appl Environ Microbiol       Date:  2018-08-17       Impact factor: 4.792

Review 5.  The effect of environmental parameters on the survival of airborne infectious agents.

Authors:  Julian W Tang
Journal:  J R Soc Interface       Date:  2009-09-22       Impact factor: 4.118

6.  Airborne fungi and bacteria in indoor and outdoor environment of the Pediatric Unit of Edirne Government Hospital.

Authors:  Suzan Okten; Ahmet Asan
Journal:  Environ Monit Assess       Date:  2011-05-25       Impact factor: 2.513

7.  Seasonal variability in size-segregated airborne bacterial particles and their characterization at different source-sites.

Authors:  Smita Agarwal
Journal:  Environ Sci Pollut Res Int       Date:  2017-04-07       Impact factor: 4.223

8.  Microbial contamination of dental unit waterlines and effect on quality of indoor air.

Authors:  Duygu Göksay Kadaifciler; Aysin Cotuk
Journal:  Environ Monit Assess       Date:  2014-01-28       Impact factor: 2.513

9.  The effect of temperature on airborne filamentous fungi in the indoor and outdoor space of a hospital.

Authors:  Fariba Abbasi; Mohammad Reza Samaei
Journal:  Environ Sci Pollut Res Int       Date:  2018-01-03       Impact factor: 4.223

10.  Detection and quantification of Wallemia sebi in aerosols by real-time PCR, conventional PCR, and cultivation.

Authors:  Qing-Yin Zeng; Sven-Olof Westermark; Asa Rasmuson-Lestander; Xiao-Ru Wang
Journal:  Appl Environ Microbiol       Date:  2004-12       Impact factor: 4.792

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.