Literature DB >> 12086302

Evaluation of tear film interference patterns and measures of tear break-up time.

Jason J Nichols1, Kelly K Nichols, Brian Puent, Mario Saracino, G Lynn Mitchell.   

Abstract

PURPOSE: The purpose of this study was to compare the agreement within and between examiners when evaluating real-time and digital photographs of TearScope Plus tear film interference patterns. We also evaluated between-examiner agreement of noninvasive digital tear break-up time (NITBUT) using the TearScope, the relation between NITBUT and tear film interference patterns, and the relation between NITBUT and tear break-up time (TBUT).
METHODS: Forty nondry eye patients were seen for digital imaging of the tear film using the TearScope Plus mounted on a slit-lamp with the EyeCap Ophthalmic Image Capture System. Two independent examiners first assessed the tear interference pattern in real-time and then captured the patterns and NITBUT digitally for a period of approximately 60 s. Each image series was later graded for interference pattern and NITBUT by the two independent, masked examiners.
RESULTS: Within-examiner comparisons of real-time and digital tear pattern photograph grading showed moderate to substantial agreement for experienced examiners (kappa for examiner 1 = 0.76 and kappa for examiner 2 = 0.55). Between-examiner agreement when grading tear patterns was also substantial in real-time (kappa = 0.72) and moderate when using digital photography (kappa = 0.59). The between-examiner mean NITBUT was 11.2+/-6.8 s and the 95% limits of agreement between examiners were -19.2 to +9.2 s. The mean TBUT was 7.6+/-10.4 s, and it was on average 3.7+/-12.0 s shorter than NITBUT (p = 0.06). Thicker tear film interference patterns graded photographically were associated with longer NITBUTs for both examiners (p = 0.001).
CONCLUSIONS: There is moderate to substantial within- and between-examiner agreement when comparing real-time and digital tear interference patterns photographs when using the TearScope. Although there is considerable between-examiner variability with the NITBUT test, the thicker lipid layer tear patterns tend to be associated with longer NITBUTs.

Entities:  

Mesh:

Year:  2002        PMID: 12086302     DOI: 10.1097/00006324-200206000-00009

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  27 in total

1.  Agreement between Automated and Traditional Measures of Tear Film Breakup.

Authors:  Stephanie M Cox; Kelly K Nichols; Jason J Nichols
Journal:  Optom Vis Sci       Date:  2015-09       Impact factor: 1.973

Review 2.  The watery eye.

Authors:  Jianhua Wang; Meixiao Shen; Lele Cui; Michael R Wang
Journal:  Curr Allergy Asthma Rep       Date:  2011-06       Impact factor: 4.806

3.  The lid wiper and muco-cutaneous junction anatomy of the human eyelid margins: an in vivo confocal and histological study.

Authors:  Erich Knop; Nadja Knop; Andrey Zhivov; Robert Kraak; Donald R Korb; Caroline Blackie; Jack V Greiner; Rudolf Guthoff
Journal:  J Anat       Date:  2011-04       Impact factor: 2.610

Review 4.  The international workshop on meibomian gland dysfunction: report of the diagnosis subcommittee.

Authors:  Alan Tomlinson; Anthony J Bron; Donald R Korb; Shiro Amano; Jerry R Paugh; E Ian Pearce; Richard Yee; Norihiko Yokoi; Reiko Arita; Murat Dogru
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-03-30       Impact factor: 4.799

5.  Precision of Epithelial Defect Measurements.

Authors:  Purak C Parikh; Nita G Valikodath; Christopher B Estopinal; Roni M Shtein; Alan Sugar; Leslie M Niziol; Maria A Woodward
Journal:  Cornea       Date:  2017-04       Impact factor: 2.651

6.  Structural and functional changes in corneal innervation after laser in situ keratomileusis and their relationship with dry eye.

Authors:  Cecilia Chao; Fiona Stapleton; Xiangtian Zhou; Shihao Chen; Shi Zhou; Blanka Golebiowski
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-08-11       Impact factor: 3.117

7.  Non-invasive assessment of tear film stability with a novel corneal topographer in Indian subjects.

Authors:  Vipul Bhandari; Jagdeesh K Reddy; Kirti Relekar; Ameya Ingawale; Neeraj Shah
Journal:  Int Ophthalmol       Date:  2016-02-18       Impact factor: 2.031

8.  Reliability and clinical applicability of a novel tear film imaging tool.

Authors:  Noémi Tóth; Eszter Szalai; Tibor Rák; Veronika Lillik; Attila Nagy; Adrienne Csutak
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-03-29       Impact factor: 3.117

9.  Turnover rate of tear-film lipid layer determined by fluorophotometry.

Authors:  H Mochizuki; M Yamada; S Hatou; K Tsubota
Journal:  Br J Ophthalmol       Date:  2009-08-18       Impact factor: 4.638

10.  Tear Film Break-up Time in Bipolar Disorder.

Authors:  Parvin Dibajnia; Mohadeseh Mohammadinia; Maryam Moghadasin; Mohammad Aghazade Amiri
Journal:  Iran J Psychiatry       Date:  2012
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.