Literature DB >> 12083302

Stimulus artifact cancellation in the serosal recordings of gastric myoelectric activity using wavelet transform.

Hualou Liang1, Zhiyue Lin.   

Abstract

Previous studies have shown that electrical stimulation of the stomach (i.e., gastric pacing) with appropriate parameters is a promising method for treatment of gastroparetic patients. The recording of gastric myoelectric activity (GMA) by serosal electrodes is often used to evaluate the effect of stimulation. However, the major problem with the measurement of GMA during gastric pacing is the stimulus artifacts which are often superimposed on the serosal recording and make analysis difficult. The frequency-domain adaptive filter has been used to reduce the stimulus artifacts but only with limited success. This paper describes a wavelet transform-based method for the reduction of stimulus artifacts in the serosal recordings of GMA. The key of this method lies in the use of the fuzzy set theory to select the stimulus artifact-related modulus maxima in the wavelet domain. Both quantitative and qualitative measures show that significant stimulus artifact cancellation was achieved through a series of computer simulations. Results from both single- and multichannel serosally recorded myoelectric signals during gastric pacing are presented to demonstrate the efficiency of the proposed method for the cancellation of stimulus artifacts.

Entities:  

Mesh:

Year:  2002        PMID: 12083302     DOI: 10.1109/TBME.2002.1010851

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

1.  Electrically evoked auditory steady state responses in cochlear implant users.

Authors:  Michael Hofmann; Jan Wouters
Journal:  J Assoc Res Otolaryngol       Date:  2009-12-22

2.  A retrofitted neural recording system with a novel stimulation IC to monitor early neural responses from a stimulating electrode.

Authors:  Yoonkey Nam; Edgar A Brown; James D Ross; Richard A Blum; Bruce C Wheeler; Stephen P DeWeerth
Journal:  J Neurosci Methods       Date:  2008-11-30       Impact factor: 2.390

3.  Iterative Covariance-Based Removal of Time-Synchronous Artifacts: Application to Gastrointestinal Electrical Recordings.

Authors:  Jonathan C Erickson; Joy Putney; Douglas Hilbert; Niranchan Paskaranandavadivel; Leo K Cheng; Greg O'Grady; Timothy R Angeli
Journal:  IEEE Trans Biomed Eng       Date:  2016-01-26       Impact factor: 4.538

4.  Evaluation of methods for extraction of the volitional EMG in dynamic hybrid muscle activation.

Authors:  Eran Langzam; Eli Isakov; Joseph Mizrahi
Journal:  J Neuroeng Rehabil       Date:  2006-11-23       Impact factor: 4.262

5.  The Use of Continuous Wavelet Transform Based on the Fast Fourier Transform in the Analysis of Multi-channel Electrogastrography Recordings.

Authors:  Dariusz Komorowski; Stanislaw Pietraszek
Journal:  J Med Syst       Date:  2015-10-29       Impact factor: 4.460

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.