Press-fit stability of uncemented hemispheric acetabular components: a comparison of three porous coating systems.

David C Markel1, Nivedita Hora, Michele Grimm.   

Abstract

Cementless acetabular components require good initial fixation to allow bony in-growth. The initial press-fit stability, important for designs that do not rely on supplemental fixation, was examined for three designs with different porous coating systems: beads, fiber mesh, and plasma spray. The ability to withstand tangential loads was determined (maximum rim loads: 122-1730 N). The plasma-sprayed acetabular cups withstood the greatest tangential load within the specified range of motion of 150 microm (P<0.01). Differences in surface preparation of titanium acetabular cups may significantly affect the initial stability of the implants in rim loading.

Mesh:

Substances:

Year:  2002        PMID: 12078880      PMCID: PMC3620875          DOI: 10.1007/s00264-001-0314-4

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  7 in total

1.  Effects of screw eccentricity on the initial stability of the acetabular cup.

Authors:  Jui-Ting Hsu; Chih-Han Chang; Kai-Nan An; Mark E Zobitz; Rapin Phimolsarnti; Ronald R Hugate; Kuo-An Lai
Journal:  Int Orthop       Date:  2006-09-01       Impact factor: 3.075

Review 2.  Evolution of total hip arthroplasty in patients younger than 30 years of age: A systematic review and meta-analysis.

Authors:  Andrew Konopitski; Chielozor Okafor; Brendan Smith; Keith Baldwin; Neil P Sheth
Journal:  Arch Orthop Trauma Surg       Date:  2022-02-07       Impact factor: 3.067

3.  Is the bone-bonding ability of a cementless total hip prosthesis enhanced by alkaline and heat treatments?

Authors:  Kazutaka So; Ayumi Kaneuji; Tadami Matsumoto; Shuichi Matsuda; Haruhiko Akiyama
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

4.  Prospective longitudinal study of one hundred patients with total hip arthroplasty using a second-generation cementless dual-mobility cup.

Authors:  Thibault Vermersch; Anthony Viste; Romain Desmarchelier; Michel-Henri Fessy
Journal:  Int Orthop       Date:  2015-09-07       Impact factor: 3.075

5.  Assessing the Acetabular Cup Implant Primary Stability by Impact Analyses: A Cadaveric Study.

Authors:  Adrien Michel; Romain Bosc; Jean-Paul Meningaud; Philippe Hernigou; Guillaume Haiat
Journal:  PLoS One       Date:  2016-11-28       Impact factor: 3.240

6.  Radiolucencies surrounding acetabular components with three-dimensional coatings: artifact or real?

Authors:  Ahmad Faizan; Philip Chuang; Carlos Aponte; Vincent Moretti; Peter F Sharkey
Journal:  Arthroplast Today       Date:  2017-07-26

7.  Impaction technique influences implant stability in low-density bone model.

Authors:  Ruben Doyle; Richard J van Arkel; Sarah Muirhead-Allwood; Jonathan R T Jeffers
Journal:  Bone Joint Res       Date:  2020-07-31       Impact factor: 5.853

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.