Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: early in vivo hemodynamic results.

Sandro Gelsomino1, Giorgio Morocutti, Paolo Da Col, Romeo Frassani, Rocco Carella, Giorgio Minen, Ugolino Livi.   

Abstract

BACKGROUND: The St. Jude Medical Regent is a new generation mechanical aortic valve.
METHODS: Between March 2000 and July 2001, this valve was implanted in the aortic position in 40 patients (21 men; mean age 59.1 +/- 9.0 years). Preoperatively, 24 patients (60%) were in New York Heart Association functional class III or IV. Eighteen patients (45%) underwent associated procedures. Mean valve size was 21.4 +/- 2.4 mm. The mean duration of follow-up was 8.5 +/- 4.5 months (range, 1 to 16 months).
RESULTS: There were no operative deaths. Early complications included one reoperation for bleeding and one transient low output syndrome. Valve replacement was followed by a significant reduction in mean and peak transaortic gradients over time (p < 0.001) and analysis of variance failed to demonstrate statistical differences between valve size over time (p = not significant). A significant reduction in left ventricular hypertrophy occurred over time (p = 0.01) in all valve sizes (p = not significant between groups): baseline left ventricular mass index was 194 g/cm2; it reduced by 22 g/cm2 (p = 0.006) at discharge. Left ventricular mass index decreased from 172 +/- 55 g/cm2 to 156 +/- 44 g/cm2 (p = 0.03) from discharge to 2 months. Further reductions were not significant. Relative wall thickness decreased from 0.57 +/- 0.13 preoperatively to 0.42 +/- 0.06 at discharge (p = 0.001), and again at 2 months (-0.2; p = not significant), and at 1 year (-0.02; p = not significant).
CONCLUSIONS: The early experience with the St. Jude Medical Regent valve has been satisfactory.

Entities:  

Mesh:

Year:  2002        PMID: 12078777     DOI: 10.1016/s0003-4975(01)03603-7

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  3 in total

1.  Clinical and echocardiographic assessment of the Medtronic Advantage aortic valve prosthesis: the Scandinavian multicentre, prospective study.

Authors:  Rune Haaverstad; Nicola Vitale; Asbjørn Karevold; Giangiuseppe Cappabianca; Arve Tromsdal; Peter Skov Olsen; Lars Köber; Halfdan Ihlen; Kjell Arne Rein; Jan L Svennevig
Journal:  Heart       Date:  2006-10-25       Impact factor: 5.994

2.  Application of Regent mechanical valve in patients with small aortic annulus: 3-year follow-up.

Authors:  Dong Zhao; Chunsheng Wang; Tao Hong; Cuizhen Pan; Changfa Guo
Journal:  J Cardiothorac Surg       Date:  2012-09-21       Impact factor: 1.637

3.  Early and mid-term outcome in terms of functional and hemodynamic performance of the st. Jude regent 19-mm aortic mechanical prosthesis versus 19-mm carpentier edwards aortic biological prosthesis.

Authors:  Edvin Prifti; Massimo Bonacchi; Fadil Ademaj; Gabriele Giunti; Giampiero Esposito; Arben Baboci; Gani Bajraktari; Altin Veshti; Aurel Demiraj; Vittorio Vanini
Journal:  J Cardiothorac Surg       Date:  2015-11-06       Impact factor: 1.637

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.