Literature DB >> 12078775

Eight-year results of aortic root replacement with the freestyle stentless porcine aortic root bioprosthesis.

Neal D Kon1, Robert D Riley, Sandy M Adair, Dalane W Kitzman, A Robert Cordell.   

Abstract

BACKGROUND: Stentless porcine aortic valves offer several advantages over traditional valves. Among these are superior hemodynamics, laminar flow patterns, lack of need for anticoagulation, and perhaps improved durability.
METHODS: One hundred four patients were operated on from September 17, 1992, to October 31, 1997, as part of a multicenter worldwide investigation of the Medtronic Freestyle stentless porcine bioprosthesis. All patients received a total aortic root replacement. The patients were evaluated postoperatively at discharge, at 3 to 6 months, and yearly by clinical examination and color flow Doppler echocardiography.
RESULTS: Operative mortality was 3.9%. No patient experienced structural valve deterioration, nonstructural deterioration, perivalvular leak, or unacceptable hemodynamic performance. At 8 years, survival was 59.8%. Freedom from thromboembolic complications was 83.3%. Freedom from postoperative endocarditis was 96.9%. Freedom from reoperation was 100%. Mean systolic gradients did not change over the time period studied. They were 6.4 +/- 3.8 mm Hg at 1 year and 6.7 +/- 2.6 mm Hg at 8 years. Correspondingly, effective orifice area was 1.9 +/- 0.7 cm2 at 1 year and 1.8 +/- 0.8 cm2 at 8 years. The incidence of any aortic insufficiency also did not change over the length of follow-up. At 1 year, 98% of patients had no or trivial aortic insufficiency and 2% had mild aortic insufficiency. At 8 years, 100% of patients evaluated were free of any aortic insufficiency.
CONCLUSIONS: The Medtronic Freestyle aortic root bioprosthesis can be used safely to replace the aortic root or aortic valve for aortic valve and aortic root pathology. Total root replacement allows optimal hemodynamic performance with no significant aortic regurgitation. Results up to 8 years show excellent survival and no signs of degeneration. Further follow-up is still needed to determine valve durability.

Entities:  

Mesh:

Year:  2002        PMID: 12078775     DOI: 10.1016/s0003-4975(02)03575-0

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  5 in total

1.  Surgical treatment of aortic abscess and fistula.

Authors:  Nilgun Bozbuga; Vedat Erentug; Hasan Basri Erdogan; Kaan Kirali; Hasan Ardal; Serpil Tas; Esat Akinci; Cevat Yakut
Journal:  Tex Heart Inst J       Date:  2004

2.  Early results of Bentall-type operations during the last 10 years: comparison of mechanical valves and stentless bioprostheses.

Authors:  Koki Nakamura; Tomohiro Asai; Mikiko Murakami; Yosuke Saitoh; Hiroki Yamaguchi
Journal:  Gen Thorac Cardiovasc Surg       Date:  2007-01

3.  Eighteen years of clinical experience with a modification of the Bentall button technique for total root replacement.

Authors:  Dimos Karangelis; Dimitrios Tzertzemelis; Alexandros A Demis; Stella Economidou; Matthew Panagiotou
Journal:  J Thorac Dis       Date:  2018-12       Impact factor: 2.895

4.  Full-root aortic valve replacement with stentless xenograft achieves superior regression of left ventricular hypertrophy compared to pericardial stented aortic valves.

Authors:  Reza Tavakoli; Christoph Auf der Maur; Xavier Mueller; Reinhard Schläpfer; Peiman Jamshidi; François Daubeuf; Nelly Frossard
Journal:  J Cardiothorac Surg       Date:  2015-02-03       Impact factor: 1.637

5.  Hospital Results of a Single Center Database for Stentless Xenograft Use in a Full Root Technique in Over 970 Patients.

Authors:  Jerry Easo; Alexander Weymann; Philipp Hölzl; Michael Horst; Harald Eichstaedt; Ahmed Mashhour; Konstantin Zhigalov; Marcin Szczechowicz; Rohit Philip Thomas; Anton Sabashnikov; Otto E Dapunt
Journal:  Sci Rep       Date:  2019-03-13       Impact factor: 4.379

  5 in total