Literature DB >> 12075963

Clutter filters adapted to tissue motion in ultrasound color flow imaging.

Steinar Bjaerum1, Hans Torp, Kjell Kristoffersen.   

Abstract

The quality of ultrasound color flow images is highly dependent on sufficient attenuation of the clutter signals originating from stationary and slowly moving tissue. Without sufficient clutter rejection, the detection of low velocity blood flow will be poor, and the velocity estimates will have a large bias. In some situations, e.g., when imaging the coronary arteries or when the operator moves the probe in search for small vessels, there is considerable movement of tissue. It has been suggested that clutter rejection can be improved by mixing down the signal with an estimate of the mean frequency prior to high pass filtering. In this paper, we compare this algorithm with several other adaptive clutter filtering algorithms using both experimental data and simulations. We found that realistic accelerations of the tissue have a large effect on the clutter rejection. The best results were obtained by mixing down the signal with non-constant phase increments estimated from the signal. This adapted the filter to a possibly accelerated tissue motion and produced a significant improvement in clutter rejection.

Mesh:

Year:  2002        PMID: 12075963     DOI: 10.1109/tuffc.2002.1009328

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  18 in total

1.  Adaptive clutter rejection filtering in ultrasonic strain-flow imaging.

Authors:  Christian Kargel; Gernot Höbenreich; Birgit Trummer; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2003-07       Impact factor: 2.725

Review 2.  Elastography: modality-specific approaches, clinical applications, and research horizons.

Authors:  Yufei Li; Jess G Snedeker
Journal:  Skeletal Radiol       Date:  2010-03-30       Impact factor: 2.199

3.  Functional tissue pulsatility imaging of the brain during visual stimulation.

Authors:  John C Kucewicz; Barbrina Dunmire; Daniel F Leotta; Heracles Panagiotides; Marla Paun; Kirk W Beach
Journal:  Ultrasound Med Biol       Date:  2007-05       Impact factor: 2.998

4.  Ultrasonic colour Doppler imaging.

Authors:  David H Evans; Jørgen Arendt Jensen; Michael Bachmann Nielsen
Journal:  Interface Focus       Date:  2011-05-06       Impact factor: 3.906

5.  Combining Slow Flow Techniques With Adaptive Demodulation for Improved Perfusion Ultrasound Imaging Without Contrast.

Authors:  Jaime Tierney; Kristy Walsh; Helen Griffith; Jennifer Baker; Daniel B Brown; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-02-07       Impact factor: 2.725

6.  Adaptive Clutter Demodulation for Non-Contrast Ultrasound Perfusion Imaging.

Authors:  Jaime Tierney; Crystal Coolbaugh; Theodore Towse; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2017-06-13       Impact factor: 10.048

7.  Quantification of Renal Stone Contrast with Ultrasound in Human Subjects.

Authors:  Bryan W Cunitz; Jonathan D Harper; Mathew D Sorensen; Yasser A Haider; Jeff Thiel; Philip C May; Ziyue Liu; Michael R Bailey; Barbrina Dunmire; Matthew Bruce
Journal:  J Endourol       Date:  2017-09-28       Impact factor: 2.942

8.  Harmonic tracking of acoustic radiation force-induced displacements.

Authors:  Joshua R Doherty; Jeremy J Dahl; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-11       Impact factor: 2.725

9.  Independent Component-Based Spatiotemporal Clutter Filtering for Slow Flow Ultrasound.

Authors:  Jaime Tierney; Jennifer Baker; Daniel Brown; Don Wilkes; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2019-11-04       Impact factor: 10.048

10.  A Spatial Coherence Beamformer Design for Power Doppler Imaging.

Authors:  Kathryn Ozgun; Jaime Tierney; Brett Byram
Journal:  IEEE Trans Med Imaging       Date:  2019-11-14       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.