PURPOSE: This randomized clinical trial examined implant overdenture (IOD) fabrication and maintenance time and costs, adjustment and repair incidence, and patient satisfaction after 1 year.
MATERIALS AND METHODS: Sixty-four patients received 2 mandibular implants and an IOD with either a bar with 2 clips or 2 ball attachments for denture retention.
RESULTS: Fabrication time, number of appointments, and chair time for adjustments were similar for the 2 denture designs. The most common adjustments for both types were to the IOD contours. Ball-attachment dentures required about 8 times longer for repairs than bar-clip prostheses. Approximately 84% of patients with ball-attachment dentures needed at least 1 repair, versus 20% of those with a bar-clip mechanism. The most common repairs were replacement of the cap spring or cap for the ball-attachment IOD and replacement of a lost or loose clip for bar-clip dentures. DISCUSSION: Patients were equally and highly satisfied with the improvements in function, comfort, and appearance with both types of IOD compared to their original conventional dentures.
CONCLUSIONS: Given equivalent levels of patient satisfaction with either method of retention and a much higher repair rate for the ball attachment, it is suggested that a bar-clip design be used rather than the particular ball attachment utilized in this study.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12074455

Source DB:  PubMed          Journal:  Int J Oral Maxillofac Implants        ISSN: 0882-2786            Impact factor:   2.804


  8 in total

1.  Radicular stud attachment: an alternative to improved retention and esthetics.

Authors:  Shanti Varghese; T V Padmanaban; R Subramanian
Journal:  J Indian Prosthodont Soc       Date:  2011-06-03

2.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

3.  Attachment systems for mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Jeong-Yol Lee; Sang-Wan Shin; S Ross Bryant
Journal:  J Adv Prosthodont       Date:  2012-11-29       Impact factor: 1.904

4.  A prospective study of early loaded single implant-retained mandibular overdentures: preliminary one-year results.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-03-15

5.  Standardizing the evaluation criteria on treatment outcomes of mandibular implant overdentures: a systematic review.

Authors:  Ha-Young Kim; Sang-Wan Shin; Jeong-Yol Lee
Journal:  J Adv Prosthodont       Date:  2014-10-21       Impact factor: 1.904

Review 6.  Implant Supported Fixed Restorations versus Implant Supported Removable Overdentures: A Systematic Review.

Authors:  Khaled Selim; Sherif Ali; Ahmed Reda
Journal:  Open Access Maced J Med Sci       Date:  2016-10-14

7.  Comparison of retentive force and wear pattern of Locator® and ADD-TOC attachments combined with CAD-CAM milled bar.

Authors:  Sung-Ki Chae; Won-Tak Cho; Jae-Won Choi; Eun-Bin Bae; Ji-Hyeon Bae; Gang-Ho Bae; Jung-Bo Huh
Journal:  J Adv Prosthodont       Date:  2022-02-25       Impact factor: 1.904

8.  Interventions for replacing missing teeth: attachment systems for implant overdentures in edentulous jaws.

Authors:  Alan Gt Payne; Nabeel Hm Alsabeeha; Momen A Atieh; Marco Esposito; Sunyoung Ma; Marwah Anas El-Wegoud
Journal:  Cochrane Database Syst Rev       Date:  2018-10-11
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.