Fully refocused gradient recalled echo (FRGRE): factors affecting flow and motion sensitivity in cardiac MRI.

Laurie B Hildebrand1, Michael H Buonocore.   

Abstract

The Fully Refocused Gradient Recalled Echo (FRGRE) magnetic resonance pulse sequence, previously reported as True FISP, was implemented and reported on a GE Signa CV/i 1.5T scanner. The purpose of this research was to optimize the pulse sequence design and scanning parameters to improve image quality for cardiac applications. A 2-D, multi-slice, multi-phase, breathold, segmented k-space, prospectively gated FRGRE sequence was implemented with TE and TR values as short as 0.9 and 3.0 msec, respectively. Pulse sequence design changes were investigated theoretically in terms of moment calculations and by assessing the quality of long- and short-axis cardiac images. The most influential scanning parameter for the improvement of image quality was both a short TR and TE. Placement of the z gradient rephaser immediately before the slice select gradient reduced the accumulated moments and improved image quality. Increasing the slice thickness from 3 to 8-10 mm significantly reduced flow artifact. The number of views per segment was doubled, without decreasing image quality, cutting breathold time in half compared to cardiac scanning with conventional sequences with longer TRs. The optimal flip angle was approximately 60 degrees. The use of a full or fractional echo had no noticeable effect on image quality. Surprisingly, the addition of flow compensation pulses significantly decreased image quality. In summary, optimization of sequence design and scanning parameters significantly reduced flow artifacts seen in FRGRE images.

Entities:  

Mesh:

Year:  2002        PMID: 12074136     DOI: 10.1081/jcmr-120003947

Source DB:  PubMed          Journal:  J Cardiovasc Magn Reson        ISSN: 1097-6647            Impact factor:   5.364


  3 in total

1.  Grading of aortic stenosis severity: a head-to-head comparison between cardiac magnetic resonance imaging and echocardiography.

Authors:  Cesare Mantini; Gabriele Di Giammarco; Jacopo Pizzicannella; Sabina Gallina; Fabrizio Ricci; Emilia D'Ugo; Marziale Marchetti; Antonio Raffaele Cotroneo; Nauman Ahmed; Chiara Bucciarelli-Ducci; Armando Tartaro; Raffaele De Caterina
Journal:  Radiol Med       Date:  2018-05-05       Impact factor: 3.469

2.  Quantification of aortic valve stenosis in MRI-comparison of steady-state free precession and fast low-angle shot sequences.

Authors:  Thomas Schlosser; Nasser Malyar; Markus Jochims; Frank Breuckmann; Peter Hunold; Oliver Bruder; Raimund Erbel; Jörg Barkhausen
Journal:  Eur Radiol       Date:  2006-10-17       Impact factor: 5.315

3.  Assessment of mitral bioprostheses using cardiovascular magnetic resonance.

Authors:  Florian von Knobelsdorff-Brenkenhoff; André Rudolph; Ralf Wassmuth; Jeanette Schulz-Menger
Journal:  J Cardiovasc Magn Reson       Date:  2010-06-23       Impact factor: 5.364

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.