Literature DB >> 12071261

A finite element model of the human knee joint for the study of tibio-femoral contact.

Tammy L Haut Donahue1, M L Hull, Mark M Rashid, Christopher R Jacobs.   

Abstract

As a step towards developing a finite element model of the knee that can be used to study how the variables associated with a meniscal replacement affect tibio-femoral contact, the goals of this study were 1) to develop a geometrically accurate three-dimensional solid model of the knee joint with special attention given to the menisci and articular cartilage, 2) to determine to what extent bony deformations affect contact behavior, and 3) to determine whether constraining rotations other than flexion/extension affects the contact behavior of the joint during compressive loading. The model included both the cortical and trabecular bone of the femur and tibia, articular cartilage of the femoral condyles and tibial plateau, both the medial and lateral menisci with their horn attachments, the transverse ligament, the anterior cruciate ligament, and the medial collateral ligament. The solid models for the menisci and articular cartilage were created from surface scans provided by a noncontacting, laser-based, three-dimensional coordinate digitizing system with an root mean squared error (RMSE) of less than 8 microns. Solid models of both the tibia and femur were created from CT images, except for the most proximal surface of the tibia and most distal surface of the femur which were created with the three-dimensional coordinate digitizing system. The constitutive relation of the menisci treated the tissue as transversely isotropic and linearly elastic. Under the application of an 800 N compressive load at 0 degrees of flexion, six contact variables in each compartment (ie., medial and lateral) were computed including maximum pressure, mean pressure, contact area, total contact force, and coordinates of the center of pressure. Convergence of the finite element solution was studied using three mesh sizes ranging from an average element size of 5 mm by 5 mm to 1 mm by 1 mm. The solution was considered converged for an average element size of 2 mm by 2 mm. Using this mesh size, finite element solutions for rigid versus deformable bones indicated that none of the contact variables changed by more than 2% when the femur and tibia were treated as rigid. However, differences in contact variables as large as 19% occurred when rotations other than flexion/extension were constrained. The largest difference was in the maximum pressure. Among the principal conclusions of the study are that accurate finite element solutions of tibio-femoral contact behavior can be obtained by treating the bones as rigid. However, unrealistic constraints on rotations other than flexion/extension can result in relatively large errors in contact variables.

Entities:  

Mesh:

Year:  2002        PMID: 12071261     DOI: 10.1115/1.1470171

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  89 in total

1.  Development of a subject-specific model to predict the forces in the knee ligaments at high flexion angles.

Authors:  Zhaochun Yang; Alexis C Wickwire; Richard E Debski
Journal:  Med Biol Eng Comput       Date:  2010-06-29       Impact factor: 2.602

2.  FEATURE-BASED MULTIBLOCK FINITE ELEMENT MESH GENERATION.

Authors:  Kiran H Shivanna; Srinivas C Tadepalli; Nicole M Grosland
Journal:  Comput Aided Des       Date:  2010-12-01       Impact factor: 3.027

Review 3.  A 'plane' explanation of anterior cruciate ligament injury mechanisms: a systematic review.

Authors:  Carmen E Quatman; Catherine C Quatman-Yates; Timothy E Hewett
Journal:  Sports Med       Date:  2010-09-01       Impact factor: 11.136

4.  Biomechanic effect of posterior cruciate ligament rupture on lateral meniscus.

Authors:  Pengfei Lei; Rongxin Sun; Yihe Hu; Kanghua Li; Zhan Liao
Journal:  Int J Clin Exp Med       Date:  2015-06-15

5.  Sensate scaffolds can reliably detect joint loading.

Authors:  C L Bliss; J A Szivek; B C Tellis; D S Margolis; A B Schnepp; J T Ruth
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2007-04       Impact factor: 3.368

6.  Multibody dynamic simulation of knee contact mechanics.

Authors:  Yanhong Bei; Benjamin J Fregly
Journal:  Med Eng Phys       Date:  2004-11       Impact factor: 2.242

Review 7.  Verification, validation and sensitivity studies in computational biomechanics.

Authors:  Andrew E Anderson; Benjamin J Ellis; Jeffrey A Weiss
Journal:  Comput Methods Biomech Biomed Engin       Date:  2007-06       Impact factor: 1.763

8.  Validation of phalanx bone three-dimensional surface segmentation from computed tomography images using laser scanning.

Authors:  Nicole A DeVries; Esther E Gassman; Nicole A Kallemeyn; Kiran H Shivanna; Vincent A Magnotta; Nicole M Grosland
Journal:  Skeletal Radiol       Date:  2007-10-25       Impact factor: 2.199

9.  Biphasic finite element contact analysis of the knee joint using an augmented Lagrangian method.

Authors:  Hongqiang Guo; Suzanne A Maher; Robert L Spilker
Journal:  Med Eng Phys       Date:  2013-03-15       Impact factor: 2.242

10.  In situ deformation of cartilage in cyclically loaded tibiofemoral joints by displacement-encoded MRI.

Authors:  D D Chan; C P Neu; M L Hull
Journal:  Osteoarthritis Cartilage       Date:  2009-05-07       Impact factor: 6.576

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.