Literature DB >> 12070118

Ventricular afterload and ventricular work in fontan circulation: comparison with normal two-ventricle circulation and single-ventricle circulation with blalock-taussig shunts.

Hideaki Senzaki1, Satoshi Masutani, Jun Kobayashi, Toshiki Kobayashi, Nozomu Sasaki, Haruhiko Asano, Shunei Kyo, Yuji Yokote, Akira Ishizawa.   

Abstract

BACKGROUND: Recent studies have indicated that there are inherent limitations associated with Fontan physiology. However, there have been no quantitative analyses of the effects of right heart bypass on ventricular afterload, hydraulic power, and resultant overall hemodynamics. Methods and Results- During routine cardiac catheterization, aortic impedance and ventricular hydraulic power were determined, both at rest and under increased ventricular work induced by dobutamine, in 17 patients with Fontan circulation, 15 patients with a single ventricle whose pulmonary circulation was maintained only by Blalock-Taussig shunts, and 13 patients who had normal 2-ventricle circulation. Both vascular resistance (nonpulsatile load on the ventricle) and pulsatile components of ventricular afterload (represented by low-frequency impedance) were significantly higher in the Fontan group than in the other groups (P<0.01), and this was associated with decreased cardiac output in the Fontan patients. In addition, hydraulic power cost per unit forward flow was 40% lower in the 2-ventricle circulation than in the single-ventricle circulation, suggesting lower ventricular efficiency in single-ventricle circulation attributable to the lack of a pulmonary ventricle. Furthermore, in the Fontan group, beta-adrenergic reserve was markedly decreased because of a limited preload reserve.
CONCLUSIONS: Fontan physiology is associated with disadvantageous ventricular power and afterload profiles and has limited ventricular reserve capacity. Thus, to improve the long-term prognosis of patients after Fontan surgery, future research should be conducted into medical interventions that can overcome these limitations inherent in Fontan circulation.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12070118     DOI: 10.1161/01.cir.0000018621.96210.72

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  30 in total

1.  Fontan "Ten Commandments" revisited and revised.

Authors:  Herbert J Stern
Journal:  Pediatr Cardiol       Date:  2010-10-20       Impact factor: 1.655

2.  Cavopulmonary assist for the failing Fontan circulation: impact of ventricular function on mechanical support strategy.

Authors:  Guruprasad A Giridharan; Mickey Ising; Michael A Sobieski; Steven C Koenig; Jun Chen; Steven Frankel; Mark D Rodefeld
Journal:  ASAIO J       Date:  2014 Nov-Dec       Impact factor: 2.872

3.  Non-invasive assessment of ventricular force-frequency relations in the univentricular circulation by tissue Doppler echocardiography: a novel method of assessing myocardial performance in congenital heart disease.

Authors:  M M H Cheung; J F Smallhorn; B W McCrindle; G S Van Arsdell; A N Redington
Journal:  Heart       Date:  2005-10       Impact factor: 5.994

4.  Effect of Fontan fenestration on regional venous oxygen saturation during exercise: further insights into Fontan fenestration closure.

Authors:  Rohit S Loomba; Michael E Danduran; Jennifer E Dixon; Rohit P Rao
Journal:  Pediatr Cardiol       Date:  2013-10-23       Impact factor: 1.655

5.  Diastolic asynchrony and myocardial dysfunction in patients with univentricular heart after Fontan operation.

Authors:  Wei Hui; Mohamed Y Abd El Rahman; Rita Schuck; Axel Rentzsch; Moustafa Yigitbasi; Stanislav Ovroutski; Fatima Lunze; Felix Berger; Hashim Abdul-Khaliq
Journal:  J Echocardiogr       Date:  2013-09-06

6.  Performance evaluation of a pediatric viscous impeller pump for Fontan cavopulmonary assist.

Authors:  Guruprasad A Giridharan; Steven C Koenig; Jeffrey Kennington; Michael A Sobieski; Jun Chen; Steven H Frankel; Mark D Rodefeld
Journal:  J Thorac Cardiovasc Surg       Date:  2012-03-14       Impact factor: 5.209

7.  Larger aortic reconstruction corresponds to diminished left pulmonary artery size in patients with single-ventricle physiology.

Authors:  Lakshmi P Dasi; Kartik S Sundareswaran; Colleen Sherwin; Diane de Zelicourt; Kirk Kanter; Mark A Fogel; Ajit P Yoganathan
Journal:  J Thorac Cardiovasc Surg       Date:  2009-10-31       Impact factor: 5.209

Review 8.  Medical management of the failing Fontan.

Authors:  N S Ghanayem; S Berger; J S Tweddell
Journal:  Pediatr Cardiol       Date:  2007 Nov-Dec       Impact factor: 1.655

9.  Exercise capacity in the Bidirectional Glenn physiology: Coupling cardiac index, ventricular function and oxygen extraction ratio.

Authors:  Carolina Vallecilla; Reza H Khiabani; Phillip Trusty; Néstor Sandoval; Mark Fogel; Juan Carlos Briceño; Ajit P Yoganathan
Journal:  J Biomech       Date:  2015-04-06       Impact factor: 2.712

10.  Assessment of Diastolic Function in Single-Ventricle Patients After the Fontan Procedure.

Authors:  Renee Margossian; Lynn A Sleeper; Gail D Pearson; Piers C Barker; Luc Mertens; Michael D Quartermain; Jason T Su; Girish Shirali; Shan Chen; Steven D Colan
Journal:  J Am Soc Echocardiogr       Date:  2016-09-10       Impact factor: 5.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.