Literature DB >> 12068156

Biexponential T2 relaxation time analysis of the brain: correlation with magnetization transfer ratio.

N Papanikolaou1, V Maniatis, J Pappas, A Roussakis, R Efthimiadou, J Andreou.   

Abstract

RATIONALE AND
OBJECTIVES: To measure T2 relaxation times of normal white and gray matter using a novel CPMG sequence and investigate if any correlation exists between magnetization transfer ratio (MTR) and T2 relaxation-related parameters.
MATERIALS AND METHODS: Seventeen normal volunteers participated on this study. A single-slice 32-echo sequence was used to calculate the T2 relaxation time of frontal and occipital white matter and cortical gray matter. T2 relaxation analysis included monoexponential and biexponential fitting whereas an F test was used to determine if biexponential fitting was statistically more accurate than monoexponential fitting. Short and long T2 constants were calculated as well as the signal fractions of each pool. MTR calculations were based on a three-dimensional gradient echo (3D FFE) proton density weighted sequence with and without an on-resonance composite prepulse. MTR and T2 relaxation times were calculated and linear regression analysis was applied.
RESULTS: Biexponential fitting was more accurate comparing with monoexponential fitting in all WM and GM regions (F > 2.47, P < 0.01). Mean values of short T2 constant for frontal white matter (fWM), occipital white matter (oWM) and gray matter (GM) were 8.10, 9.36, and 22.23 milliseconds, respectively, whereas the mean values of long T2 constant were 85.1, 93.02, and 118.72 milliseconds, respectively. Mean restricted water percentages (RWP)-corresponding to the signal fraction of the protons with short T2-for the fWM, oWM, and GM were 22.01%, 23.36%, and 18.7%. Mean free water percentages (FWP)-corresponding to the signal fraction of the protons with long T2-for the fWM, oWM and GM were 77.99%, 76.64%, and 81.3%. Mean MTR values for fWM, oWM and GM were 68.4%, 68.2%, and 61.3%, respectively. No significant correlation was found in fWM and oWM between MTR and RWP, short and long T2 components while a moderate correlation existed in GM between MTR and RWP (r = 0.57; P = 0.02), MTR and short T2 component (r = -0.69; P = 0.004) and MTR and long T2 component (r = -0.62; P = 0.012).
CONCLUSIONS: Two proton pools with different T2 decay characteristics can be separated in normal gray and white matter when using a multiecho sequence with short echo spacing. MTR and T2 relaxation times were significantly correlated in gray matter and the combination of both types of measurements may be helpful in studying myelin related disorders.

Entities:  

Mesh:

Year:  2002        PMID: 12068156     DOI: 10.1097/00004424-200207000-00001

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  8 in total

1.  MTR variations in normal adult brain structures using balanced steady-state free precession.

Authors:  Meritxell Garcia; Monika Gloor; Oliver Bieri; Stephan G Wetzel; Ernst-Wilhelm Radue; Klaus Scheffler
Journal:  Neuroradiology       Date:  2010-05-18       Impact factor: 2.804

2.  Early detection of global cerebral anoxia: improved accuracy by high-b-value diffusion-weighted imaging with long echo time.

Authors:  Khin K Tha; Satoshi Terae; Toru Yamamoto; Kohsuke Kudo; Chihiro Takahashi; Masaki Oka; Shinji Uegaki; Kazuo Miyasaka
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

3.  Evidence of rapid ongoing brain development beyond 2 years of age detected by fiber tracking.

Authors:  X-Q Ding; Y Sun; H Braass; T Illies; H Zeumer; H Lanfermann; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-24       Impact factor: 3.825

4.  Macromolecule content influences proton diffusibility in gliomas.

Authors:  Einar Goebell; Jens Fiehler; Susanne Siemonsen; Ole Vaeterlein; Oliver Heese; Christian Hagel; Xiao-Qi Ding; Jan-Hendrik Buhk; Michael Groth; Thomas Kucinski
Journal:  Eur Radiol       Date:  2011-07-16       Impact factor: 5.315

5.  Sensitivity calibration with a uniform magnetization image to improve arterial spin labeling perfusion quantification.

Authors:  Weiying Dai; Philip M Robson; Ajit Shankaranarayanan; David C Alsop
Journal:  Magn Reson Med       Date:  2011-04-26       Impact factor: 4.668

6.  T2 relaxation time analysis in patients with multiple sclerosis: correlation with magnetization transfer ratio.

Authors:  Nickolas Papanikolaou; Eufrosini Papadaki; Spyros Karampekios; Martha Spilioti; Thomas Maris; Panos Prassopoulos; Nicholas Gourtsoyiannis
Journal:  Eur Radiol       Date:  2003-11-05       Impact factor: 5.315

7.  Multiexponential T2 and magnetization transfer MRI of demyelination and remyelination in murine spinal cord.

Authors:  Cheryl R McCreary; Thorarin A Bjarnason; Viktor Skihar; J Ross Mitchell; V Wee Yong; Jeff F Dunn
Journal:  Neuroimage       Date:  2009-01-21       Impact factor: 6.556

8.  Magnetization transfer imaging to assess tumour response after chemoradiotherapy in rectal cancer.

Authors:  Milou H Martens; Doenja M J Lambregts; Nickolas Papanikolaou; Styliani Alefantinou; Monique Maas; Georgios C Manikis; Kostantinos Marias; Robert G Riedl; Geerard L Beets; Regina G H Beets-Tan
Journal:  Eur Radiol       Date:  2015-06-12       Impact factor: 5.315

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.