Abstract

Although autogenous saphenous vein remains the standard for coronary and infrapopliteal bypass, many patients do not have a suitable vein. Attempts at developing a small-caliber vascular graft have failed largely due to occlusion, neointimal hyperplasia, or aneurismal degradation. We have designed and characterized a novel small-caliber vascular xenograft that may overcome these failure modes. To reduce immune reactions, porcine common carotid arteries were decellularized by enzymatic and detergent treatments. Histology and electron microscopic examination showed complete removal of cellular components while the extracellular matrix structure remained intact. To reduce thrombogeneity, decellularized vascular grafts were covalently linked with heparin. The efficiency of heparin linkage was demonstrated with toluidine blue staining and the antithrombogeneity of the heparin-treated grafts was demonstrated with a clot time test. Mechanical testing of the graft was performed. Decellularized-heparin-treated grafts were similar in compliance to fresh vessels and burst testing showed grafts to withstand pressures exceeding 10 times physiologic blood pressure. There was no difference in suture retention strength between fresh vessels and decellularized-heparin-treated grafts. Decellularized, heparinized grafts were implanted in dogs as carotid artery bypass grafts and showed smooth muscle cells densely populating the wall, and endothelial cells lining the lumen by two months. This study provides a new strategy to develop a small-caliber vascular graft with excellent mechanical properties, antithrombogeneity, and tissue compatibility.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12062176     DOI: 10.1016/s1350-4533(02)00010-3

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  48 in total

Review 1.  Engineering of bypass conduits to improve patency.

Authors:  S T Rashid; H J Salacinski; B J Fuller; G Hamilton; A M Seifalian
Journal:  Cell Prolif       Date:  2004-10       Impact factor: 6.831

2.  A novel ovine ex vivo arteriovenous shunt model to test vascular implantability.

Authors:  Haofan Peng; Evan M Schlaich; Sindhu Row; Stelios T Andreadis; Daniel D Swartz
Journal:  Cells Tissues Organs       Date:  2011-10-14       Impact factor: 2.481

Review 3.  Tissue Engineering at the Blood-Contacting Surface: A Review of Challenges and Strategies in Vascular Graft Development.

Authors:  Daniel Radke; Wenkai Jia; Dhavan Sharma; Kemin Fena; Guifang Wang; Jeremy Goldman; Feng Zhao
Journal:  Adv Healthc Mater       Date:  2018-05-07       Impact factor: 9.933

Review 4.  Development of small-diameter vascular grafts.

Authors:  Xinwen Wang; Peter Lin; Qizhi Yao; Changyi Chen
Journal:  World J Surg       Date:  2007-04       Impact factor: 3.352

Review 5.  Stem cell sources for vascular tissue engineering and regeneration.

Authors:  Vivek K Bajpai; Stelios T Andreadis
Journal:  Tissue Eng Part B Rev       Date:  2012-07-03       Impact factor: 6.389

Review 6.  Biomaterials to prevascularize engineered tissues.

Authors:  Lei Tian; Steven C George
Journal:  J Cardiovasc Transl Res       Date:  2011-09-03       Impact factor: 4.132

7.  Mechanocompatible Polymer-Extracellular-Matrix Composites for Vascular Tissue Engineering.

Authors:  Bin Jiang; Rachel Suen; Jiao-Jing Wang; Zheng J Zhang; Jason A Wertheim; Guillermo A Ameer
Journal:  Adv Healthc Mater       Date:  2016-04-24       Impact factor: 9.933

8.  Development of a mechanically tuneable 3D scaffold for vascular reconstruction.

Authors:  Maritza Rodriguez; Cassandra Juran; Mark McClendon; Cyril Eyadiel; Peter S McFetridge
Journal:  J Biomed Mater Res A       Date:  2012-07-24       Impact factor: 4.396

Review 9.  Biomaterials for vascular tissue engineering.

Authors:  Swathi Ravi; Elliot L Chaikof
Journal:  Regen Med       Date:  2010-01       Impact factor: 3.806

10.  Viscoelastic response of human skin to low magnitude physiologically relevant shear.

Authors:  Brian Holt; Anubhav Tripathi; Jeffrey Morgan
Journal:  J Biomech       Date:  2008-07-30       Impact factor: 2.712

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.