Influence of room lighting on grey-scale perception with a CRT-and a TFT monitor display.

R Haak1, M J Wicht, M Hellmich, G Nowak, M J Noack.   

Abstract

OBJECTIVES: To determine the influence of ambient lighting on grey-scale perception using a cathode-ray tube (CRT) and a thin film transistor (TFT) computer display.
METHODS: A cathode ray tube (Nokia XS 446) and a liquid crystal display (Panasonic LC 50S) were used at reduced room lighting (70 lux) and under conditions recommended for a dental operatory (1000 lux). Twenty-seven observers examined twice a modified SMPTE test pattern [0 to 255; 255 to 0] grey-scale values. The corresponding contrast differences were allocated to four ranges of grey levels (I: 0-63; II: 64-127; III: 128-191; IV: 192-255). The influences of monitor type, grey-scale range and illumination were evaluated by means of repeated measures analysis of variance.
RESULTS: Detection of differences in monochromatic intensity was significantly earlier with reduced lighting (P<0.0001). When full ambient lighting was used, the TFT display was superior compared to the CRT monitor in ranges II and III (P<0.0001), whereas no differences could be detected for grey intensities between 0 and 63 (P=0.71) and between 192 and 255 (P=0.36).
CONCLUSIONS: Background lighting hampers grey-scale perception on computer displays. In this study of one TFT and one CRT monitor, the TFT in full ambient lighting was associated with earlier detection of grey scale differences than CRT.

Entities:  

Mesh:

Year:  2002        PMID: 12058268     DOI: 10.1038/sj/dmfr/4600668

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  7 in total

1.  Effect of room illuminance on monitor black level luminance and monitor calibration.

Authors:  K Chakrabarti; R V Kaczmarek; J A Thomas; A Romanyukha
Journal:  J Digit Imaging       Date:  2004-01-30       Impact factor: 4.056

2.  Diagnostic performance of liquid crystal and cathode-ray-tube monitors in brain computed tomography.

Authors:  Gerald Pärtan; Rudolf Mayrhofer; Michael Urban; Manfred Wassipaul; Ludwig Pichler; Walter Hruby
Journal:  Eur Radiol       Date:  2003-02-19       Impact factor: 5.315

3.  Comparison of liquid crystal versus cathode ray tube display for the detection of simulated chest lesions.

Authors:  Elisabeth Oschatz; Mathias Prokop; Martina Scharitzer; Michael Weber; Csilla Balassy; Cornelia Schaefer-Prokop
Journal:  Eur Radiol       Date:  2004-09-08       Impact factor: 5.315

4.  A Subjective Assessment of Perceived Clarity of Indirect Digital Images and Processed Digital Images with Conventional Intra-oral Periapical Radiographs.

Authors:  Suchetha N Malleshi; Mahima V G; Anudeepa Raina; Karthikeya Patil
Journal:  J Clin Diagn Res       Date:  2013-08-01

5.  Grey value contrast sensitivity of dental practitioners in function of luminance and age.

Authors:  Wolfgang Jacquet; Roberto G Cleymaet; Peter Bottenberg
Journal:  Dentomaxillofac Radiol       Date:  2019-02-26       Impact factor: 2.419

6.  Could standardizing "commercial off-the-shelf" (COTS) monitors to the DICOM part 14: GSDF improve the presentation of dental images? A visual grading characteristics analysis.

Authors:  D J McIlgorm; C Lawinski; S Ng; J P McNulty
Journal:  Dentomaxillofac Radiol       Date:  2013-08-29       Impact factor: 2.419

7.  Comparison of occlusal caries detection using the ICDAS criteria on extracted teeth or their photographs.

Authors:  P Bottenberg; W Jacquet; C Behrens; V Stachniss; A Jablonski-Momeni
Journal:  BMC Oral Health       Date:  2016-09-07       Impact factor: 2.757