Literature DB >> 12058086

Comparison of motor conduction techniques in the diagnosis of carpal tunnel syndrome.

Ming-Hong Chang1, S-J Wei, H-L Chiang, H-M Wang, P F Hsieh, S-Y Huang.   

Abstract

OBJECTIVE: To compare the sensitivities of motor wrist-to-palm (W-P) conduction velocity and two median-ulnar motor latency differences with that of sensory W-P conduction velocity in the diagnosis of carpal tunnel syndrome (CTS).
METHODS: This study included 116 consecutive patients with CTS (160 hands) referred for evaluation and 100 volunteers who served as controls. Median motor and sensory nerve responses with wrist and palm stimulation allowed for the determination of motor and sensory W-P CV (W-P MCV and SCV). Two motor distal latency (MDL) differences between the median-thenar and ulnar-hypothenar (M-U) muscles and between the median-second lumbrical and ulnar-interossei muscles (2L-INT) were measured and calculated. The mean values of controls plus or minus 2.5 SD served as the normal limits.
RESULTS: Among the 160 hands with suspected CTS, 11 (6.88%) had normal electrodiagnostic studies and 149 (93.1%) had at least one abnormal electrodiagnostic study. Among the 149 hands with an abnormality, 139 (86.88%) had abnormal W-P MCV and 129 (80.63%) had abnormal W-P SCV. The sensitivity for 2L-INT was 77.5%, and it was 70% for M-U, 68.75% for median MDL, and 73.75% for sensory distal latency. Combining W-P MCV and W-P SCV allowed for the detection of abnormalities in 147 hands (91.88%) and yielded a markedly improved diagnostic rate compared with W-P SCV alone.
CONCLUSION: Motor W-P conduction study is more valuable and no more difficult than sensory W-P conduction study for the diagnosis of CTS. In patients with suspected CTS in whom the results of conventional nerve conduction studies are normal, studying both motor and sensory W-P conduction increases the diagnostic yield.

Entities:  

Mesh:

Year:  2002        PMID: 12058086     DOI: 10.1212/wnl.58.11.1603

Source DB:  PubMed          Journal:  Neurology        ISSN: 0028-3878            Impact factor:   9.910


  8 in total

1.  Levels of agreement of nerve conduction studies and symptoms in workers at risk of carpal tunnel syndrome.

Authors:  Francesco S Violante; Roberta Bonfiglioli; Lucia Isolani; Giovanni B Raffi
Journal:  Int Arch Occup Environ Health       Date:  2004-11-05       Impact factor: 3.015

2.  Lumbrical-interosseous recording technique versus routine electrodiagnostic methods in the diagnosis of carpal tunnel syndrome.

Authors:  Figen Yılmaz; Osman Hakan Gündüz; Gülseren Akyüz
Journal:  Turk J Phys Med Rehabil       Date:  2017-08-17

3.  The Sensitivity and Specificity of Nerve Conduction Studies for Diagnosis of Carpal Tunnel Syndrome: A Systematic Review.

Authors:  Cory Demino; John R Fowler
Journal:  Hand (N Y)       Date:  2019-06-17

4.  Value of F-wave studies on the electrodiagnosis of carpal tunnel syndrome.

Authors:  Murat Alemdar
Journal:  Neuropsychiatr Dis Treat       Date:  2015-08-31       Impact factor: 2.570

5.  A study of interpolation method in diagnosis of carpal tunnel syndrome.

Authors:  Alireza Ashraf; Abbas Daghaghzadeh; Mahshid Naseri; Aref Nasiri; Maryam Fakheri
Journal:  Ann Indian Acad Neurol       Date:  2013-10       Impact factor: 1.383

6.  Role of concentric needle Single Fiber Electromyography in detection of subclinical motor involvement in carpal tunnel syndrome.

Authors:  Aliaa A Tawfeek; Amani M Nawito; Radwa M Azmy; Amr Hassan; Lamia M Afifi; Saly H Elkholy
Journal:  Egypt J Neurol Psychiatr Neurosurg       Date:  2018-04-25

7.  Comparison of Interpolation Methods in the Diagnosis of Carpal Tunnel Syndrome

Authors:  Veysel Alcan; Murat Zinnuroğlu; Gülçin Kaymak Karataş; Elliot Bodofsky
Journal:  Balkan Med J       Date:  2018-06-01       Impact factor: 2.021

8.  Sensitivities of conventional and new electrophysiological techniques in carpal tunnel syndrome and their relationship to body mass index.

Authors:  Recep Aygül; Hzir Ulvi; Dilcan Kotan; Mutlu Kuyucu; Recep Demir
Journal:  J Brachial Plex Peripher Nerve Inj       Date:  2009-07-31
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.