| Literature DB >> 29780222 |
Aliaa A Tawfeek1, Amani M Nawito1, Radwa M Azmy1, Amr Hassan2, Lamia M Afifi1, Saly H Elkholy1.
Abstract
BACKGROUND: Conventional motor nerve conduction studies are usually normal in early and mild carpal tunnel syndrome (CTS). Single-fiber electromyography (SFEMG) measures the mean consecutive difference (MCD) as an expression of the variability in impulse transmission over the motor endplates and along the nerve fibers distally to the last branching point and along the muscle fibers.Application of concentric needle SFEMG in a group of CTS patients who showed pure sensory abnormalities in nerve conduction studies to examine for subclinical motor involvement.Entities:
Keywords: Abductor pollicis brevis; Carpal tunnel syndrome; Concentric needle; Mean consecutive difference; Single-fiber electromyography
Year: 2018 PMID: 29780222 PMCID: PMC5954771 DOI: 10.1186/s41983-018-0004-4
Source DB: PubMed Journal: Egypt J Neurol Psychiatr Neurosurg ISSN: 1110-1083
Values of median sensory conduction studies of the patient group
| Sensory conduction studies | Minimum | Maximum | Mean ± SD |
|---|---|---|---|
| Median onset latency(ms) | 2.6 | 3.8 | 2.9 ± 0.3 |
| Median peak latency(ms) | 3.1 | 4.5 | 3.7 ± 0.4 |
| Median amplitude (μV) | 7.0 | 69.1 | 32.1 ± 16.9 |
| Median distal CV | 35.0 | 50.8 | 44.3 ± 4.3 |
| Median vs. ulnar 4th digit comparative sensory study | 0.5 | 2.3 | 1.2 ± 0.5 |
CV conduction velocity
Fig. 1SFEMG potentials recorded from APB during voluntary contraction. Trace obtained from a control subject. MCD is 22.5 μs
Fig. 2SFEMG potentials recorded from APB during voluntary contraction. Trace obtained from a CTS patient. MCD is = 40.3 μs
MCD of the APB, EDC, and ADM
| Muscle | APB | EDC | ADM | |||
|---|---|---|---|---|---|---|
| Patients | Control | Patients | Control | Patients | Control | |
|
| ||||||
| | 25.00 ± 9.1 | 23.56 ± 7.88 | 24.58 ± 8.73 | 25.71 ± 9.00 | 23.37 ± 8.1 | 24.12 ± 7.78 |
| | 0.038 | 0.12 | 0.25 | |||
ABD abductor pollicis brevis, EDC extensor digitorum communis, ADM abductor digiti minimi, MCD mean consecutive difference
p value < 0.05 = significant