Literature DB >> 12056282

[MACS-TL polyaxial screw XL. A new concept for increasing stability of ventral spondylodesis in the presence of dorsal injuries].

M Schultheiss1, H J Wilke, L Claes, L Kinzl, E Hartwig.   

Abstract

The influence of additional dorsal structure damage on anterior stabilization of thoracolumbar fracture is still unknown. Screw cement enhancement is a possibility to reinforce the stability of anterior instrumentation. A new anchorage system has been developed for fixation of anterior stabilization devices, adapted through geometric optimization and the possibility of optional additional cementation after screw insertion in cases of poor bone quality. Is this enhancement strong enough to support a single anterior procedure such as the thoracoscopic technique and still compensate for dorsal instability? A biomechanical in vitro study simulating an anterior corpectomy, strut grafting, and overbridging stabilization with a dorsal laminectomy as dorsal structure damage was performed, and the primary stability parameters were evaluated with and without screw cement enhancement. The additional cementation enhanced the primary stability of the anterior instrumentation and compensated for dorsal instability.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12056282     DOI: 10.1007/s00132-001-0282-9

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  6 in total

1.  Factors affecting the interface of cervical spine facet screws placed in the technique by Roy-Camille et al.

Authors:  T R Pitzen; S Zenner; D Barbier; T Georg; W I Steudel
Journal:  Eur Spine J       Date:  2004-03-27       Impact factor: 3.134

2.  Primary stability of anterior lumbar stabilization: interdependence of implant type and endplate retention or removal.

Authors:  Christian H Flamme; Nadine von der Heide; Caroline Heymann; Christof Hurschler
Journal:  Eur Spine J       Date:  2005-08-10       Impact factor: 3.134

3.  Pullout strength of anterior spinal instrumentation: a product comparison of seven screws in calf vertebral bodies.

Authors:  Konrad Seller; Dieter Wahl; Alexander Wild; Rüdiger Krauspe; Erich Schneider; Berend Linke
Journal:  Eur Spine J       Date:  2007-02-02       Impact factor: 3.134

4.  [Therapy indications and options for skeletal metastases].

Authors:  M Schultheiss; A von Baer; F Gebhard; L Kinzl; M Arand
Journal:  Urologe A       Date:  2007-08       Impact factor: 0.639

5.  Biomechanical in vitro comparison of different mono- and bisegmental anterior procedures with regard to the strategy for fracture stabilisation using minimally invasive techniques.

Authors:  Markus Schultheiss; Erich Hartwig; Michael Sarkar; Lothar Kinzl; Lutz Claes; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2005-02-04       Impact factor: 3.134

6.  Is polymethyl methacrylate a viable option for salvaging lateral mass screw failure in the subaxial cervical spine?

Authors:  Michael A Gallizzi; Craig A Kuhns; Tyler J Jenkins; Ferris M Pfeiffer
Journal:  Global Spine J       Date:  2014-10-10
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.