Literature DB >> 12049485

Evaluation of USP apparatus 3 for dissolution testing of immediate-release products.

Lawrence X Yu1, Jin T Wang, Ajaz S Hussain.   

Abstract

We sought to evaluate whether U.S. Pharmacopeia (USP) apparatus 3 can be used as an alternative to USP apparatus 2 for dissolution testing of immediate-release (IR) dosage forms. Highly soluble drugs, metoprolol and ranitidine, and poorly soluble drugs, acyclovir and furosemide, were chosen as model drugs. The dissolution profiles of both innovator and generic IR products were determined using USP apparatus 2 at 50 rpm and apparatus 3 at 5, 15, and 25 dips per minute (dpm). The dissolution profiles from USP apparatus 3 were compared to those from USP apparatus 2 using the f(2) similarity test. The dissolution profile from USP apparatus 3 generally depends on the agitation rate, with a faster agitation rate producing a faster dissolution rate. It was found that USP apparatus 3 at the extreme low end of the possible agitation range, such as 5 dpm, gave hydrodynamic conditions equivalent to USP apparatus 2 at 50 rpm. With appropriate agitation rate, USP apparatus 3 can produce similar dissolution profiles to USP apparatus 2 or distinguish dissolution characteristics for the IR products of metoprolol, ranitidine, and acyclovir. Incomplete dissolution was observed for the furosemide tablets using USP apparatus 3. Although it is primarily designed for the release testing of extended-release products, USP apparatus 3 may be used for the dissolution testing of IR products of highly soluble drugs, such as metoprolol and ranitidine, and some IR products of poorly soluble drugs, such as acyclovir. USP apparatus 3 offers the advantages of avoiding cone formation and mimicking the changes in physiochemical conditions and mechanical forces experienced by products in the gastrointestinal tract.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12049485      PMCID: PMC2751286          DOI: 10.1208/ps040101

Source DB:  PubMed          Journal:  AAPS PharmSci        ISSN: 1522-1059


  5 in total

1.  A new method of dissolution in vitro, the "Bio-Dis" apparatus: comparison with the rotating bottle method and in vitro: in vivo correlations.

Authors:  B Esbelin; E Beyssac; J M Aiache; G K Shiu; J P Skelly
Journal:  J Pharm Sci       Date:  1991-10       Impact factor: 3.534

2.  In vivo-in vitro correlation of salbutamol release from a controlled release osmotic pump delivery system.

Authors:  C Civiale; W A Ritschel; G K Shiu; J M Aiache; E Beyssac
Journal:  Methods Find Exp Clin Pharmacol       Date:  1991-09

3.  USP dissolution apparatus 3 (reciprocating cylinder): instrument parameter effects on drug release from sustained release formulations.

Authors:  B R Rohrs; D L Burch-Clark; M J Witt; D J Stelzer
Journal:  J Pharm Sci       Date:  1995-08       Impact factor: 3.534

4.  Direct estimation of the in vivo dissolution of spironolactone, in two particle size ranges, using the single-pass perfusion technique (Loc-I-Gut) in humans.

Authors:  L Bønløkke; L Hovgaard; H G Kristensen; L Knutson; H Lennernäs
Journal:  Eur J Pharm Sci       Date:  2001-01       Impact factor: 4.384

5.  Drug release from spray layered and coated drug-containing beads: effects of pH and comparison of different dissolution methods.

Authors:  W Sorasuchart; J Wardrop; J W Ayres
Journal:  Drug Dev Ind Pharm       Date:  1999-10       Impact factor: 3.225

  5 in total
  7 in total

1.  Comparison of three dissolution apparatuses for testing calcium phosphate pellets used as ibuprofen delivery systems.

Authors:  Emilie Chevalier; Marylène Viana; Aymeric Artaud; Lisette Chomette; Samir Haddouchi; Gille Devidts; Dominique Chulia
Journal:  AAPS PharmSciTech       Date:  2009-05-14       Impact factor: 3.246

2.  Bio-dis and the paddle dissolution apparatuses applied to the release characterization of ketoprofen from hypromellose matrices.

Authors:  Bianca Ramos Pezzini; Humberto Gomes Ferraz
Journal:  AAPS PharmSciTech       Date:  2009-06-03       Impact factor: 3.246

3.  Understanding biorelevant drug release from a novel thermoplastic capsule by considering microstructural formulation changes during hydration.

Authors:  Zdravka Misic; Raphael Urbani; Thomas Pfohl; Katharina Muffler; Georg Sydow; Martin Kuentz
Journal:  Pharm Res       Date:  2013-08-07       Impact factor: 4.200

4.  Computational fluid dynamics simulation of hydrodynamics in USP apparatus 3-the influence of dip rate.

Authors:  Satish Perivilli; Maziar Kakhi; Erika Stippler
Journal:  Pharm Res       Date:  2014-11-19       Impact factor: 4.200

5.  In vitro evaluation of dissolution behavior for a colon-specific drug delivery system (CODES) in multi-pH media using United States Pharmacopeia apparatus II and III.

Authors:  Jinhe Li; Libo Yang; Sheila M Ferguson; Tom J Hudson; Shunsuke Watanabe; Masataka Katsuma; Joseph A Fix
Journal:  AAPS PharmSciTech       Date:  2002       Impact factor: 3.246

6.  Drug formulations intended for the global market should be tested for stability under tropical climatic conditions.

Authors:  P G Risha; C Vervaet; G Vergote; L Van Bortel; J P Remon
Journal:  Eur J Clin Pharmacol       Date:  2003-04-30       Impact factor: 2.953

7.  Velocity Field Visualization in USP Dissolution Apparatus 3 Using Particle Image Velocimetry.

Authors:  Satish Perivilli; Richard Prevost; Erika Stippler
Journal:  Pharm Res       Date:  2017-04-13       Impact factor: 4.200

  7 in total