A comparison of stainless steel hand and rotary nickel-titanium instrumentation using a silicone impression technique.

J L Chen1, H H Messer.   

Abstract

BACKGROUND: Root canal preparation using rotary nickel-titanium instruments has been reported to be superior to hand instrumentation in terms of root canal shape, centring and frequency of procedural errors. The purpose of this study was to evaluate canal preparations using a sequential silicone impression technique to assess root canal morphology.
METHODS: Pre-operative canal impressions were obtained from 24 extracted single-rooted premolars. Canals were randomly assigned to be firstly, instrumented with stainless steel K-type files or rotary nickel-titanium instruments (Profile), then further apically enlarged with rotary nickel-titanium instruments (Profile or Lightspeed). Post instrumentation impressions were taken and digitally photographed in a bucco-lingual and mesio-distal orientation at low-power magnification. Images were evaluated for procedural defects, changes in canal curvature, canal enlargement and canal rounding at 1, 3 and 7mm from the working length.
RESULTS: Silicone impressions could accurately reproduce the detailed root canal morphology of single-canal premolars. Repeated impressions of each canal using a standardized procedure allowed a detailed comparison of instrumentation techniques at various stages. Hand instrumentation incurred more errors than rotary nickel-titanium instrumentation (Profile). Further apical enlargement using Lightspeed instruments incurred fewer errors than with Profile instruments. Differences among techniques were highly significant (p<0.005). All techniques resulted in slight canal straightening, as well as rounder and enlarged canals particularly in the apical third.
CONCLUSIONS: Rotary nickel-titanium instrumentation, especially Lightspeed, may produce better canal shape by reducing procedural errors.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12035951     DOI: 10.1111/j.1834-7819.2002.tb00297.x

Source DB:  PubMed          Journal:  Aust Dent J        ISSN: 0045-0421            Impact factor:   2.291


  6 in total

1.  Biomechanical preparation in primary molars using manual and three NiTi instruments: a cone-beam-computed tomographic in vitro study.

Authors:  A Manker; M Solanki; A Tripathi; M L Jain
Journal:  Eur Arch Paediatr Dent       Date:  2019-09-05

2.  Cyclic fatigue resistance of four nickel-titanium rotary instruments: a comparative study.

Authors:  Eugenio Pedullà; Gianluca Plotino; Nicola Maria Grande; Alfio Pappalardo; Ernesto Rapisarda
Journal:  Ann Stomatol (Roma)       Date:  2012-08-09

3.  Alterations of the Danger Zone after Preparation of Curved Root Canals Using WaveOne with Reverse Rotation or Reciprocation Movements.

Authors:  Yazdan Shantiaee; Omid Dianat; Payam Paymanpour; Golnaz Nahvi; Mohammad Ali Ketabi; Golbarg Kolahi Ahari
Journal:  Iran Endod J       Date:  2015-07-01

4.  Estrogen deficiency reduces the dentinogenic capacity of rat lower incisors.

Authors:  Tao Xu; Ming Yan; Yanping Wang; Zhanwei Wang; Lizhe Xie; Chunbo Tang; Guangdong Zhang; Jinhua Yu
Journal:  J Mol Histol       Date:  2013-08-22       Impact factor: 2.611

5.  Comparison of removed dentin thickness with hand and rotary instruments.

Authors:  Shahriar Shahriari; Hasan Abedi; Mahdi Hashemi; Seyed Mohsen Jalalzadeh
Journal:  Iran Endod J       Date:  2009-04-17

6.  Cyclic fatigue resistance of OneShape, Reciproc, and WaveOne: An in vitro comparative study.

Authors:  Alberto Dagna; Claudio Poggio; Riccardo Beltrami; Marco Colombo; Marco Chiesa; Stefano Bianchi
Journal:  J Conserv Dent       Date:  2014-05
  6 in total