Literature DB >> 12033593

Fracture mechanisms of retrieved titanium screw thread in dental implant.

Ken'ichi Yokoyama1, Tetsuo Ichikawa, Hiroki Murakami, Youji Miyamoto, Kenzo Asaoka.   

Abstract

Titanium and its alloy are increasingly attracting attention for use as biomaterials. However, delayed fracture of titanium dental implants has been reported, and factors affecting the acceleration of corrosion and fatigue have to be determined. The fractured surface of a retrieved titanium screw and metallurgical structures of a dental implant system were analyzed. The outer surface of the retrieved screw had a structure different from that of the as-received screw. It was confirmed that a shear crack initiated at the root of the thread and propagated into the inner section of the screw. Gas chromatography revealed that the retrieved screw had absorbed a higher amount of hydrogen than the as-received sample. The grain structure of a titanium screw, immersed in a solution known to induce hydrogen absorption, showed features similar to those of the retrieved screw. It was concluded that titanium in a biological environment absorbs hydrogen and this may be the reason for delayed fracture of a titanium implant.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12033593     DOI: 10.1016/s0142-9612(01)00380-5

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  15 in total

1.  Influence of bone insertion level of the implant on the fracture strength of different connection designs: an in vitro study.

Authors:  Sergio Alexandre Gehrke; Miriam Souza Dos Santos Vianna; Berenice Anina Dedavid
Journal:  Clin Oral Investig       Date:  2013-07-17       Impact factor: 3.573

Review 2.  Multi-Scale Surface Treatments of Titanium Implants for Rapid Osseointegration: A Review.

Authors:  Qingge Wang; Peng Zhou; Shifeng Liu; Shokouh Attarilar; Robin Lok-Wang Ma; Yinsheng Zhong; Liqiang Wang
Journal:  Nanomaterials (Basel)       Date:  2020-06-26       Impact factor: 5.076

Review 3.  Hypersensitivity to titanium: a less explored area of research.

Authors:  Vasantha Vijayaraghavan; Ajay V Sabane; K Tejas
Journal:  J Indian Prosthodont Soc       Date:  2012-07-13

4.  Biological characterization of a new silicon based coating developed for dental implants.

Authors:  M Martínez-Ibáñez; M J Juan-Díaz; I Lara-Saez; A Coso; J Franco; M Gurruchaga; J Suay Antón; Isabel Goñi
Journal:  J Mater Sci Mater Med       Date:  2016-03-02       Impact factor: 3.896

Review 5.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

6.  Clinical management and microscopic characterisation of fatigue-induced failure of a dental implant. Case report.

Authors:  S Capodiferro; G Favia; M Scivetti; G De Frenza; R Grassi
Journal:  Head Face Med       Date:  2006-06-22       Impact factor: 2.151

7.  Adult stem cells properties in terms of commitment, aging and biological safety of grit-blasted and Acid-etched ti dental implants surfaces.

Authors:  Chiara Gardin; Letizia Ferroni; Eriberto Bressan; José L Calvo-Guirado; Marco Degidi; Adriano Piattelli; Barbara Zavan
Journal:  Int J Mol Cell Med       Date:  2014

8.  Improved in vitro angiogenic behavior on anodized titanium dioxide nanotubes.

Authors:  Ernesto Beltrán-Partida; Benjamín Valdéz-Salas; Aldo Moreno-Ulloa; Alan Escamilla; Mario A Curiel; Raúl Rosales-Ibáñez; Francisco Villarreal; David M Bastidas; José M Bastidas
Journal:  J Nanobiotechnology       Date:  2017-01-31       Impact factor: 10.435

Review 9.  An Overview of the Mechanical Integrity of Dental Implants.

Authors:  Keren Shemtov-Yona; Daniel Rittel
Journal:  Biomed Res Int       Date:  2015-10-25       Impact factor: 3.411

Review 10.  Electrochemical Cathodic Polarization, a Simplified Method That Can Modified and Increase the Biological Activity of Titanium Surfaces: A Systematic Review.

Authors:  Jose Carlos Bernedo Alcazar; Mabel Miluska Suca Salas; Marcus Cristian Muniz Conde; Luiz Alexandre Chisini; Flávio Fernando Demarco; Sandra Beatriz Chaves Tarquinio; Neftali Lenin Villarreal Carreño
Journal:  PLoS One       Date:  2016-07-21       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.