Literature DB >> 12032474

Visual assessment of left ventricular perfusion and function with electrocardiography-gated SPECT has high intraobserver and interobserver reproducibility among experienced nuclear cardiologists and cardiology trainees.

Peter G Danias1, Alan W Ahlberg, Mark I Travin, Nicholas C Mahr, Joseph E Abreu, Dominic Marini, April Mann, Jeffrey F Mather, William E Boden, Gary V Heller.   

Abstract

BACKGROUND: Stress electrocardiography (ECG)-gated single photon emission computed tomography (SPECT) for assessment of left ventricular perfusion and function improves the confidence of interpretation and enhances specificity for detection of coronary artery disease. The reproducibility of visual interpretation of ECG-gated SPECT images and the significance of training and experience have not been reported previously in a large series of consecutive patients. We evaluated both intraobserver and interobserver agreement of interpretation of ECG-gated SPECT images among 3 cardiology trainees and 3 experienced nuclear cardiologists from 3 institutions. METHODS AND
RESULTS: Three nuclear cardiologists and 3 cardiology trainees who had fulfilled American College of Cardiology/American Society of Nuclear Cardiology Core Cardiology Training Symposium (ACC/ASNC COCATS) guidelines for level II training in nuclear cardiology independently evaluated 106 consecutive technetium 99m sestamibi SPECT images with ECG gating of either the stress or rest images. All cases were interpreted blindly, twice in random sequence, without clinical data. We assessed intraobserver and interobserver agreement for myocardial perfusion, left ventricular regional and global systolic function, and overall clinical impression, by means of percent agreement and Cohen's kappa statistic. Intraobserver agreement was good (82%-92%, kappa = 0.54-0.84) for assessment of myocardial perfusion, systolic function, and overall impression. Interobserver agreement was also good, ranging from 65% to 90% (kappa = 0.32-0.76), with better agreement found for assessment of function (77%-85%, kappa = 0.52-0.7) than for perfusion (65%-80%, kappa = 0.32-0.6). For all measures, there were no significant differences in reproducibility between nuclear cardiologists and cardiology trainees.
CONCLUSIONS: Interpretation of ECG-gated SPECT images has high reproducibility and agreement among both nuclear cardiologists and cardiology trainees.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12032474     DOI: 10.1067/mnc.2002.121233

Source DB:  PubMed          Journal:  J Nucl Cardiol        ISSN: 1071-3581            Impact factor:   5.952


  17 in total

1.  Effectiveness of nuclear cardiology training guidelines: a comparison of trainees with experienced readers.

Authors:  R J Golub; J R McClellan; S D Herman; M I Travin; G M Kline; P W Aitken; J I Baron; A W Ahlberg; G V Heller
Journal:  J Nucl Cardiol       Date:  1996 Mar-Apr       Impact factor: 5.952

2.  Agreement in human interpretation of analog thallium myocardial perfusion images.

Authors:  J E Atwood; D Jensen; V Froelicher; K Witztum; K Gerber; E Gilpin; W Ashburn
Journal:  Circulation       Date:  1981-09       Impact factor: 29.690

3.  Interpretive reproducibility of stress Tc-99m sestamibi tomographic myocardial perfusion imaging.

Authors:  R J Golub; A W Ahlberg; J R McClellan; S D Herman; M I Travin; J F Mather; P W Aitken; J I Baron; G V Heller
Journal:  J Nucl Cardiol       Date:  1999 May-Jun       Impact factor: 5.952

4.  Is the addition of ECG gating to technetium-99m sestamibi SPET of value in the assessment of myocardial viability? An evaluation based on two-dimensional echocardiography following revascularization.

Authors:  P González; T Massardo; A Muñoz; J Jofré; A Rivera; J Yovanovich; E Maiers; F Ayala; P Humeres; A Ramírez; M Arriagada; A Zavala
Journal:  Eur J Nucl Med       Date:  1996-10

5.  Comparative diagnostic accuracy of Tl-201 and Tc-99m sestamibi SPECT imaging (perfusion and ECG-gated SPECT) in detecting coronary artery disease in women.

Authors:  R Taillefer; E G DePuey; J E Udelson; G A Beller; Y Latour; F Reeves
Journal:  J Am Coll Cardiol       Date:  1997-01       Impact factor: 24.094

6.  Functional assessment with electrocardiographic gated single-photon emission computed tomography improves the ability of technetium-99m sestamibi myocardial perfusion imaging to predict myocardial viability in patients undergoing revascularization.

Authors:  M G Levine; C C McGill; A W Ahlberg; M P White; S Giri; B Shareef; D Waters; G V Heller
Journal:  Am J Cardiol       Date:  1999-01-01       Impact factor: 2.778

7.  Reduced variability of interpretation and improved image quality with a technetium 99m myocardial perfusion agent: comparison of thallium 201 and technetium 99m-labeled tetrofosmin.

Authors:  R C Hendel; M A Parker; F J Wackers; P Rigo; A Lahiri; B L Zaret
Journal:  J Nucl Cardiol       Date:  1994 Nov-Dec       Impact factor: 5.952

8.  Technetium-99m sestamibi myocardial imaging: same-day rest-stress studies and dipyridamole.

Authors:  R Taillefer
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

9.  Combined assessment of myocardial perfusion and left ventricular function with exercise technetium-99m sestamibi gated single-photon emission computed tomography can differentiate between ischemic and nonischemic dilated cardiomyopathy.

Authors:  P G Danias; A W Ahlberg; B A Clark; F Messineo; M G Levine; C C McGill; A Mann; J Clive; J E Dougherty; D D Waters; G V Heller
Journal:  Am J Cardiol       Date:  1998-11-15       Impact factor: 2.778

10.  Using gated technetium-99m-sestamibi SPECT to characterize fixed myocardial defects as infarct or artifact.

Authors:  E G DePuey; A Rozanski
Journal:  J Nucl Med       Date:  1995-06       Impact factor: 10.057

View more
  16 in total

1.  Analysis of serial images: a challenge and an opportunity.

Authors:  Ami E Iskandrian; Ernest V Garcia; Tracy Faber
Journal:  J Nucl Cardiol       Date:  2007-10-29       Impact factor: 5.952

2.  Observer variability in the evaluation of dual-isotope Tl-201/Tc-99m sestamibi rest/stress myocardial perfusion SPECT in men and women with known or suspected stable angina pectoris.

Authors:  Allan Johansen; Poul Flemming Høilund-Carlsen; Henrik Wulff Christensen; Peter Grupe; Annegrete Veje; Werner Vach; Torben Haghfelt
Journal:  J Nucl Cardiol       Date:  2004 Nov-Dec       Impact factor: 5.952

3.  ASNC imaging guidelines for nuclear cardiology procedures : Standardized reporting of nuclear cardiology procedures.

Authors:  Peter L Tilkemeier; Jamieson Bourque; Rami Doukky; Rupa Sanghani; Richard L Weinberg
Journal:  J Nucl Cardiol       Date:  2017-09-15       Impact factor: 5.952

4.  Minimal rest activity for SPECT myocardial perfusion imaging in a one-day stress-first protocol.

Authors:  J D van Dijk; J A van Dalen; S Knollema; M Mouden; J P Ottervanger; P L Jager
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-11-08       Impact factor: 9.236

5.  Segmental and global left ventricular function assessment using gated SPECT with a semiconductor Cadmium Zinc Telluride (CZT) camera: phantom study and clinical validation vs cardiac magnetic resonance.

Authors:  Alban Bailliez; Tanguy Blaire; Frédéric Mouquet; R Legghe; B Etienne; Damien Legallois; Denis Agostini; Alain Manrique
Journal:  J Nucl Cardiol       Date:  2014-05-09       Impact factor: 5.952

6.  Prediction of revascularization after myocardial perfusion SPECT by machine learning in a large population.

Authors:  Reza Arsanjani; Damini Dey; Tigran Khachatryan; Aryeh Shalev; Sean W Hayes; Mathews Fish; Rine Nakanishi; Guido Germano; Daniel S Berman; Piotr Slomka
Journal:  J Nucl Cardiol       Date:  2014-12-06       Impact factor: 5.952

7.  Two-position supine/prone myocardial perfusion SPECT (MPS) imaging improves visual inter-observer correlation and agreement.

Authors:  Reza Arsanjani; Sean W Hayes; Mathews Fish; Aryeh Shalev; Rine Nakanishi; Louise E J Thomson; John D Friedman; Guido Germano; Daniel S Berman; Piotr Slomka
Journal:  J Nucl Cardiol       Date:  2014-05-08       Impact factor: 5.952

8.  Automatic and visual reproducibility of perfusion and function measures for myocardial perfusion SPECT.

Authors:  Yuan Xu; Sean Hayes; Iftikhar Ali; Terrence D Ruddy; R Glenn Wells; Daniel S Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2010-10-21       Impact factor: 5.952

9.  Improved accuracy of myocardial perfusion SPECT for detection of coronary artery disease by machine learning in a large population.

Authors:  Reza Arsanjani; Yuan Xu; Damini Dey; Vishal Vahistha; Aryeh Shalev; Rine Nakanishi; Sean Hayes; Mathews Fish; Daniel Berman; Guido Germano; Piotr J Slomka
Journal:  J Nucl Cardiol       Date:  2013-05-24       Impact factor: 5.952

10.  Regional wall-motion abnormalities on post-stress electrocardiographic-gated technetium-99m sestamibi single-photon emission computed tomography imaging predict cardiac events.

Authors:  Athanasios Kapetanopoulos; Alan W Ahlberg; Cynthia C Taub; Deborah M Katten; Gary V Heller
Journal:  J Nucl Cardiol       Date:  2007 Nov-Dec       Impact factor: 5.952

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.