Literature DB >> 12012180

Determination of Cr3+, CrO42-, and Cr2O72- in environmental matrixes by high-performance liquid chromatography with diode-array detection (HPLC-DAD).

S Cathum1, C E Brown, W Wong.   

Abstract

A high-performance liquid chromatographic method with diode array detection (HPLC-DAD), based on chelation with ammonium pyrrolidinedithiocarbamate (APDC), has been developed for the determination of chromium species. Determination of Cr3+, CrO42-, and Cr2O72- was performed for standards and synthetic environmental matrixes. This method is robust, rugged, and can be used for rapid routine determination of chromium species with high precision and reliability. Sample pretreatment is simple. The method is capable of discriminating not only between Cr(III) and Cr(VI) but also between the chemical forms of Cr(VI) - CrO42- and Cr2O72-. By analysis of numerous samples the method has been shown to be selective, sensitive, and free from matrix interference, which is crucial for the determination of chromium species in difficult-to-analyze environmental matrixes. This method has been validated by means of an interlaboratory study. Although different speciation techniques were used during this study, there was good agreement between results from the two laboratories. The method detection limits were 7 and 4 mg L(-1) for Cr3+ and Cr2O72-, respectively. Recoveries of the analytes from spiked samples were 98% and 100% for Cr3+ and Cr2O72-, respectively. Both were based on a 10-mL sample volume spiked with 0.4 mg L(-1) chromium.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12012180     DOI: 10.1007/s00216-002-1292-0

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  3 in total

1.  Yellow-emissive carbon dots as a fluorescent probe for chromium(VI).

Authors:  Félicité Pacifique Mutuyimana; Juanjuan Liu; Stanislas Nsanzamahoro; Min Na; Hongli Chen; Xingguo Chen
Journal:  Mikrochim Acta       Date:  2019-02-06       Impact factor: 5.833

2.  Paper Strip and Ceramic Potentiometric Platforms Modified with Nano-Sized Polyaniline (PANi) for Static and Hydrodynamic Monitoring of Chromium in Industrial Samples.

Authors:  Saad S M Hassan; Ayman H Kamel; Abd El-Galil E Amr; M Abdelwahab Fathy; Mohamed A Al-Omar
Journal:  Molecules       Date:  2020-01-31       Impact factor: 4.411

3.  A New Cr3+ Electrochemical Sensor Based on ATNA/Nafion/Glassy Carbon Electrode.

Authors:  Reda M El-Shishtawy; Mohammed M Rahman; Tahir Ali Sheikh; Muhammad Nadeem Arshad; Fatimah A M Al-Zahrani; Abdullah M Asiri
Journal:  Materials (Basel)       Date:  2020-06-12       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.