Literature DB >> 12010541

Comparison of ATP and in vivo bioluminescence for assessing the efficiency of immunomagnetic sorbents for live Escherichia coli O157:H7 cells.

W Sun1, F Khosravi, H Albrechtsen, L Y Brovko, M W Griffiths.   

Abstract

AIMS: To develop methods to assess the efficiency of immunomagnetic separation (IMS). METHODS AND
RESULTS: The capturing efficiency of biosorbents for Escherichia coli O157:H7, constructed using streptavidin-coated magnetic beads and biotinylated antibodies, was tested using both in vivo and ATP bioluminescence. Both methods were suitable for the enumeration of bacteria captured by the biosorbents. The level of both ATP and in vivo bioluminescence depended on the media used, but was unaffected by the magnetic beads. The capture efficiency depended on time and sample volume, but did not depend on the length of spacer arm of the biotinylation agent. For cell concentrations of <or= 105 cfu ml-1, in a 1-ml sample volume, nearly 80-85% recovery of the pathogen was observed after 0.5 h of incubation. For an 11-ml sample containing 104 cfu ml-1, maximum recovery (50% of cells) was achieved only after 2 h incubation.
CONCLUSIONS: The detection limit of an ATP-based bioluminescent assay for E. coli O157:H7 was reduced by 1 log cycle after optimization of IMS. The bioluminescent methods could be used for screening and testing the affinity of antibodies or other affinity elements of biosorbents towards live bacterial cells. SIGNIFICANCE AND IMPACT OF THE STUDY: Bioluminescent assays provide an easy way to optimize conditions for the capture of bacteria by biosorbents in real time.

Entities:  

Mesh:

Substances:

Year:  2002        PMID: 12010541     DOI: 10.1046/j.1365-2672.2002.01639.x

Source DB:  PubMed          Journal:  J Appl Microbiol        ISSN: 1364-5072            Impact factor:   3.772


  5 in total

Review 1.  Working principle and application of magnetic separation for biomedical diagnostic at high- and low-field gradients.

Authors:  Sim Siong Leong; Swee Pin Yeap; JitKang Lim
Journal:  Interface Focus       Date:  2016-12-06       Impact factor: 3.906

2.  Dynabeads protein G antibody conjugates combined with modified brain heart infusion broth for the enrichment and separation of Bacillus cereus in artificially contaminated vegetables.

Authors:  Shuai Wei; Fereidoun Forghani; Youn-Seo Park; Byung-Jae Park; Kun-Ho Seo; Deog-Hwan Oh
Journal:  Food Sci Biotechnol       Date:  2016-06-30       Impact factor: 2.391

3.  Highly efficient and specific separation of Staphylococcus aureus from lettuce and milk using Dynabeads protein G conjugates.

Authors:  Shuai Wei; Byung-Jae Park; Kun-Ho Seo; Deog-Hwan Oh
Journal:  Food Sci Biotechnol       Date:  2016-10-31       Impact factor: 2.391

4.  Bioluminescent assay of microbial ATP in postmortem tissues for the estimation of postmortem interval.

Authors:  Qian Liu; Qing Sun; Yan Liu; Lan Zhou; Na Zheng; Liang Liu
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2009-12-29

5.  Bacterial detection based on polymerase chain reaction and microbead dielectrophoresis characteristics.

Authors:  Zhenhao Ding; Hiromichi Kasahara; Michihiko Nakano; Junya Suehiro
Journal:  IET Nanobiotechnol       Date:  2017-08       Impact factor: 1.847

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.