Literature DB >> 11997289

Endovascular aneurysm repair: Magnetic resonance monitoring of histological organization processes in the excluded aneurysm.

Michael Bernhard Pitton1, Ralf Patrick Schmenger, Achim Neufang, Moritz Anton Konerding, Christoph Düber, Manfred Thelen.   

Abstract

BACKGROUND: The purpose of the present study was to systematically analyze the histopathologic organization processes in excluded aneurysms after endovascular stenting and to develop a noninvasive monitoring method for these processes using MRI. METHODS AND
RESULTS: In 36 mongrel dogs, autologous aortic aneurysms were created. Endovascular treatment was performed using covered stents. Follow-up was after 1 week, 6 weeks, and 6 months. MRI was performed with T2-weighted turbo-spin-echo sequences and T1-weighted spin-echo sequences and was repeated after contrast bolus with gadolinium. Histopathologic findings were correlated to signal intensities (SIs) of MRI images. SIs of distinct areas were analyzed and related to the SI of the reference tissue (SI ratio). The histological organization process was gradated in the following 4 classes: class 0, detritus without organization; classes I and II, connective tissue proliferation with increasing fiber synthesis; and class III, dense fibrous connective tissue. The SI ratios of T2-weighted images were significantly reduced from 4.76 in detritus (0) to 1.70 in dense fibrous connective tissue (III) as a function of histopathologic classes. SI ratios of T1-weighted images were reduced from 1.84 (0) to 1.12 (III). Contrast bolus with gadolinium-DTPA showed no change of SI ratio in detritus (0.99) but an increase from 1.12 (I) to 1.70 (III) as organization increased.
CONCLUSIONS: The histological organization of excluded aneurysms can be monitored by MRI. Progressive organization is indicated by decreasing SIs in T2- and an increasing signal increase in T1-weighted images after gadolinium bolus.

Entities:  

Mesh:

Year:  2002        PMID: 11997289     DOI: 10.1161/01.cir.0000014972.94443.ef

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  On the relative impact of intraluminal thrombus heterogeneity on abdominal aortic aneurysm mechanics.

Authors:  Joseph Leach; Evan Kao; Chengcheng Zhu; David Saloner; Michael D Hope
Journal:  J Biomech Eng       Date:  2019-06-29       Impact factor: 2.097

2.  Prospective, intraindividual comparison of MRI versus MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms.

Authors:  Mario Alerci; Michel Oberson; Antonella Fogliata; Augusto Gallino; Peter Vock; Rolf Wyttenbach
Journal:  Eur Radiol       Date:  2008-12-23       Impact factor: 5.315

3.  Utility of Noncontrast Magnetic Resonance Angiography for Aneurysm Follow-Up and Detection of Endoleaks after Endovascular Aortic Repair.

Authors:  Hiroshi Kawada; Satoshi Goshima; Kota Sakurai; Yoshifumi Noda; Kimihiro Kajita; Yukichi Tanahashi; Nobuyuki Kawai; Narihiro Ishida; Katsuya Shimabukuro; Kiyoshi Doi; Masayuki Matsuo
Journal:  Korean J Radiol       Date:  2020-12-21       Impact factor: 3.500

4.  Detecting endoleaks after endovascular AAA repair with a minimally invasive, implantable, telemetric pressure sensor: an in vitro study.

Authors:  Fabian Springer; Roland Schlierf; Joachim-Georg Pfeffer; Andreas H Mahnken; Uwe Schnakenberg; Thomas Schmitz-Rode
Journal:  Eur Radiol       Date:  2007-03-06       Impact factor: 7.034

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.