Literature DB >> 11995847

Ventricular assist device support for management of sustained ventricular arrhythmias.

Panayotis Fasseas1, Steven P Kutalek, Fania L Samuels, Elena C Holmes, Louis E Samuels.   

Abstract

We describe herein the cases of 2 patients who had ventricular arrhythmias. In one, a short-term biventricular assist device, the ABIOMED BVS 5000, was placed because the patient had sustained ventricular tachycardia and could not be weaned from cardiopulmonary bypass. Excellent hemodynamic support was maintained for several days while the antiarrhythmic therapy was maximized. Sinus rhythm was restored, and the patient was successfully weaned from the ventricular assist device. However, the substrate for the arrhythmia persisted, and a recurrence, 1 week later, resulted in the patient's death. In the 2nd patient, the use of an implantable left ventricular assist device was successful in temporarily alleviating the ventricular tachycardia associated with ischemic cardiomyopathy. However, after 2 days of device assistance, the patient experienced a recurrence of the tachycardia, which degenerated into ventricular fibrillation with a marked deterioration in the patient's hemodynamics. The arrhythmia persisted despite multiple attempts at external cardioversion, and internal cardioversion and placement of an automatic implantable cardioverter-defibrillator were necessary. This treatment, along with repeated boluses of amiodarone, led to successful suppression of the arrhythmias, and the patient eventually underwent transplantation. The mechanical hemodynamic support of the circulation by ventricular assist devices was effective in supporting these 2 patients who had sustained ventricular arrhythmias.

Entities:  

Mesh:

Year:  2002        PMID: 11995847      PMCID: PMC101266     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  5 in total

1.  Refractory ventricular tachycardia as an indication for ventricular assist device support.

Authors:  M T Swartz; G A Lowdermilk; L R McBride
Journal:  J Thorac Cardiovasc Surg       Date:  1999-12       Impact factor: 5.209

2.  Stabilisation of medically refractory ventricular arrhythmia by intra-aortic balloon counterpulsation.

Authors:  G D Fotopoulos; M J Mason; S Walker; N S Jepson; D J Patel; A G Mitchell; C D Ilsley; V E Paul
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

3.  Malignant ventricular arrhythmias are well tolerated in patients receiving long-term left ventricular assist devices.

Authors:  M C Oz; E A Rose; J Slater; J J Kuiper; K A Catanese; H R Levin
Journal:  J Am Coll Cardiol       Date:  1994-12       Impact factor: 24.094

4.  Circulatory support for myocardial infarction with ventricular arrhythmias.

Authors:  W L Holman; G D Roye; R C Bourge; D C McGiffin; S S Iyer; J K Kirklin
Journal:  Ann Thorac Surg       Date:  1995-05       Impact factor: 4.330

5.  Successful biventricular circulatory support as a bridge to cardiac transplantation during prolonged ventricular fibrillation and asystole.

Authors:  D J Farrar; J D Hill; L A Gray; T A Galbraith; E Chow; J J Hershon
Journal:  Circulation       Date:  1989-11       Impact factor: 29.690

  5 in total
  2 in total

1.  First experience of percutaneous radio-frequency ablation for atrial flutter and atrial fibrillation in a patient with HeartMate II left ventricular assist device.

Authors:  Philippe Maury; Clement Delmas; Charlotte Trouillet; Mark S Slaughter; Olivier Lairez; Michel Galinier; Jerome Roncalli; David Bertrand; Lydie Mathevet; Alexandre Duparc; Michelle Salvador; Marc Delay; Camille Dambrin
Journal:  J Interv Card Electrophysiol       Date:  2010-10       Impact factor: 1.900

2.  Windkessel model of hemodynamic state supported by a pulsatile ventricular assist device in premature ventricle contraction.

Authors:  Keun Her; Joon Yeong Kim; Ki Moo Lim; Seong Wook Choi
Journal:  Biomed Eng Online       Date:  2018-02-02       Impact factor: 2.819

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.