Doses near the surface during total-body irradiation with 15 MV X-rays.

A Kassaee1, Y Xiao, P Bloch, J Goldwein, D I Rosenthal, B E Bjärngard.   

Abstract

An extended source-surface distance (SSD) is often employed in total-body irradiation (TBI) to obtain fields sufficiently large to encompass the total body. It is clinically desirable to administer a uniform dose to all tissues, including the surface, especially to counteract the skin-sparing of high-energy X-rays. The electrons generated from the air contribute more to the dose near the surface at extended distances than at regular SSDs. However, if further increase of the dose at shallow depths is desired a spoiler can be employed. Monte Carlo simulations were used to study these effects for the electron component of the beam and the parameters needed for the pencil-beam dose calculation of this component. Measurements were performed to confirm these studies. The energy spectrum of electrons generated in air is independent of SSD. All the electrons in the beam, however, originate from the spoiler when one is used. The spectrum of these electrons is nearly independent of the SSD. The pencil-beam dose kernels were calculated using the derived electron spectra. To calculate doses in the buildup region with and without a spoiler, we use one pencil-beam kernel for the electrons generated in air and one for the electrons generated from the spoiler. Measured depth-dose data agreed with the calculation results. Copyright 2002 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11992396     DOI: 10.1002/ijc.10349

Source DB:  PubMed          Journal:  Int J Cancer        ISSN: 0020-7136            Impact factor:   7.396


  4 in total

1.  Dose distribution homogeneity in two TBI techniques-Analysis of 208 irradiated patients conducted in Stanislaw Leszczynski Memorial Hospital, Katowice.

Authors:  Aneta Kawa-Iwanicka; Włodzimierz Lobodziec; Marcin Dybek; Dorota Nenko; Tomasz Iwanicki
Journal:  Rep Pract Oncol Radiother       Date:  2012-08-21

2.  Influence of Air Gap under Bolus in the Dosimetry of a Clinical 6 MV Photon Beam.

Authors:  Dilson Lobo; Sourjya Banerjee; Challapalli Srinivas; Ramamoorthy Ravichandran; Suman Kumar Putha; P U Prakash Saxena; Shreyas Reddy; Johan Sunny
Journal:  J Med Phys       Date:  2020-10-13

3.  Automatic treatment planning for VMAT-based total body irradiation using Eclipse scripting.

Authors:  Jose R Teruel; Sameer Taneja; Paulina E Galavis; K Sunshine Osterman; Allison McCarthy; Martha Malin; Naamit K Gerber; Christine Hitchen; David L Barbee
Journal:  J Appl Clin Med Phys       Date:  2021-02-10       Impact factor: 2.102

4.  A Monte Carlo evaluation of beam characteristics for total body irradiation at extended treatment distances.

Authors:  Roumiana Chakarova; Marcus Krantz
Journal:  J Appl Clin Med Phys       Date:  2014-05-08       Impact factor: 2.102