Literature DB >> 11981785

Techniques for performing multidetector-row computed tomographic angiography.

G D Rubin1.   

Abstract

The introduction of multidetector-row computed tomography (CT) scanners has substantially improved the quality and ease of performing CT angiography. CT angiography is a robust method of volumetric vascular imaging that offers benefits over conventional angiography. As CT angiography has become a mainstream examination in many radiology departments, a discussion of techniques toward optimizing CT angiography performed with multidetector-row CT scanners is important. Key principles for optimizing spiral CT acquisition are discussed, and an explanation of multidetector-row CT principles germane to peripheral vascular imaging is presented. A discussion of contrast medium administration strategies ensues, with attention toward injection protocol and bolus timing. An overview of 3-dimensional visualization techniques is subsequently presented, followed by some general rules for CT angiographic interpretation. The article concludes with anatomically directed protocol considerations for the carotid and intracranial circulation, thoracic aorta, pulmonary arteries, abdominal aortoiliac system, renal arteries, and lower extremity arterial inflow and run-off. Copyright 2001 by W.B. Saunders Company

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11981785     DOI: 10.1053/tvir.2001.22966

Source DB:  PubMed          Journal:  Tech Vasc Interv Radiol        ISSN: 1557-9808


  14 in total

1.  [Recurrent rectal cancer: diagnosis by contrast enhancement in MD-CT].

Authors:  C A Stückle
Journal:  Radiologe       Date:  2005-11       Impact factor: 0.635

2.  Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer.

Authors:  Hideki Hyodoh; Yoshimi Katagiri; Toyohiko Sakai; Kazusa Hyodoh; Hidenari Akiba; Masato Hareyama
Journal:  Eur Radiol       Date:  2005-03-11       Impact factor: 5.315

3.  Evaluation of an improved technique for automated center lumen line definition in cardiovascular image data.

Authors:  Hugo A F Gratama van Andel; Erik Meijering; Aad van der Lugt; Henri A Vrooman; Cecile de Monyé; Rik Stokking
Journal:  Eur Radiol       Date:  2005-09-17       Impact factor: 5.315

4.  Multi-detector row CT angiography in the assessment of carotid artery disease in symptomatic patients: comparison with rotational angiography and digital subtraction angiography.

Authors:  Marja Berg; Zishu Zhang; Aki Ikonen; Petri Sipola; Reetta Kälviäinen; Hannu Manninen; Ritva Vanninen
Journal:  AJNR Am J Neuroradiol       Date:  2005-05       Impact factor: 3.825

5.  Prediction of aortic peak enhancement in monophasic contrast injection protocols at multidetector CT: phantom and patient studies.

Authors:  Kazuo Awai; Yoshiharu Nakayama; Takeshi Nakaura; Yumi Yanaga; Yoshitaka Tamura; Masahiro Hatemura; Yoshinori Funama; Yasuyuki Yamashita
Journal:  Radiat Med       Date:  2007-01-25

6.  Diagnostic role of 64-slice multidetector row CT scan and CT venogram in cases of cerebral venous thrombosis.

Authors:  Anand B Gaikwad; Bharat A Mudalgi; Kiran B Patankar; Jitendra K Patil; Dhananjay V Ghongade
Journal:  Emerg Radiol       Date:  2008-04-24

7.  Atherosclerotic splenic artery aneurysm in a decompensated cirrhotic patient.

Authors:  Radu Badea; Vasile Andreica; Cosmin Caraiani; Bogdan Procopet
Journal:  J Med Ultrason (2001)       Date:  2013-02-22       Impact factor: 1.314

Review 8.  Diagnosis and management of atherosclerotic renal artery stenosis: improving patient selection and outcomes.

Authors:  Christopher J White; Jeffrey W Olin
Journal:  Nat Clin Pract Cardiovasc Med       Date:  2009-03

9.  The role of CT and MRI in the assessment of peripheral vascular disease.

Authors:  Franz von Ziegler; Marco A Costa
Journal:  Curr Cardiol Rep       Date:  2007-09       Impact factor: 2.931

10.  Diagnostic value of multidetector-row CT angiography in the evaluation of thrombosis of the cerebral venous sinuses.

Authors:  J Linn; B Ertl-Wagner; K C Seelos; M Strupp; M Reiser; H Brückmann; R Brüning
Journal:  AJNR Am J Neuroradiol       Date:  2007-05       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.