Literature DB >> 15761717

Creation of individual ideally shaped stents using multi-slice CT: in vitro results from the semi-automatic virtual stent (SAVS) designer.

Hideki Hyodoh1, Yoshimi Katagiri, Toyohiko Sakai, Kazusa Hyodoh, Hidenari Akiba, Masato Hareyama.   

Abstract

To plan stent-grafting for thoracic aortic aneurysm with complicated morphology, we created a virtual stent-grafting program [Semi Automatic Virtual Stent (SAVS) designer] using three-dimensional CT data. The usefulness of the SAVS designer was evaluated by measurement of transformed anatomical and straight stents. Curved model images (source, multi-planer reconstruction and volume rendering) were created, and a hollow virtual stent was produced by the SAVS designer. A straight Nitinol stent was transformed to match the curved configuration of the virtual stent. The accuracy of the anatomical stent was evaluated by experimental strain phantom studies in comparison with the straight stent. Mean separation length was 0 mm in the anatomical stent [22 mm outer diameter (OD)] and 5 mm in the straight stent (22 mm OD). The straight stent strain voltage was four times that of the anatomical stent at the stent end. The anatomical stent is useful because it fits the curved structure of the aorta and reduces the strain force compared to the straight stent. The SAVS designer can help to design and produce the anatomical stent.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15761717     DOI: 10.1007/s00330-004-2587-7

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  15 in total

1.  Prediction of aortoiliac stent-graft length: comparison of measurement methods.

Authors:  M Tillich; B B Hill; D S Paik; K Petz; S Napel; C K Zarins; G D Rubin
Journal:  Radiology       Date:  2001-08       Impact factor: 11.105

Review 2.  Techniques for performing multidetector-row computed tomographic angiography.

Authors:  G D Rubin
Journal:  Tech Vasc Interv Radiol       Date:  2001-03

3.  Computer-assisted analysis of three-dimensional MR angiograms.

Authors:  Marcela Hernández-Hoyos; Maciej Orkisz; Philippe Puech; Catherine Mansard-Desbleds; Philippe Douek; Isabelle E Magnin
Journal:  Radiographics       Date:  2002 Mar-Apr       Impact factor: 5.333

4.  Periprosthetic leak and rupture after endovascular repair of abdominal aortic aneurysm: the significance of device design for long-term results.

Authors:  K Krohg-Sørensen; M Brekke; A Drolsum; K Kvernebo
Journal:  J Vasc Surg       Date:  1999-06       Impact factor: 4.268

5.  Prediction of aortoiliac stent graft length: comparison of a semiautomated computed tomography angiography method and calibrated aortography.

Authors:  Kenneth Coenegrachts; Hans Rigauts; Jan De Letter
Journal:  J Comput Assist Tomogr       Date:  2003 Mar-Apr       Impact factor: 1.826

6.  Measurement of the aorta and its branches with helical CT.

Authors:  G D Rubin; D S Paik; P C Johnston; S Napel
Journal:  Radiology       Date:  1998-03       Impact factor: 11.105

7.  Quantitative determination of age-related geometric changes in the normal abdominal aorta.

Authors:  D Fleischmann; T J Hastie; F C Dannegger; D S Paik; M Tillich; C K Zarins; G D Rubin
Journal:  J Vasc Surg       Date:  2001-01       Impact factor: 4.268

8.  Endovascular placement of a nitinol-ePTFE stent-graft for abdominal aortic aneurysms: initial and midterm results.

Authors:  Fabiola Cartes-Zumelzu; Johannes Lammer; Thomas Hoelzenbein; Manfred Cejna; Maria Schoder; Siegfried Thurnher; Georg Kretschmer
Journal:  J Vasc Interv Radiol       Date:  2002-05       Impact factor: 3.464

9.  Comparison of the utility of CT scans and intravascular ultrasound in endovascular aortic grafting.

Authors:  C Verbin; M Scoccianti; G Kopchok; C Donayre; R A White
Journal:  Ann Vasc Surg       Date:  1995-09       Impact factor: 1.466

10.  Aneurysm neck diameter after endovascular repair of abdominal aortic aneurysms.

Authors:  Mohammad F Badran; Derek A Gould; Irfan Raza; Richard G McWilliams; Oliver Brown; Peter L Harris; Geoffrey L Gilling-Smith; John Brennan; Donna White; Shaun Meakin; Peter C Rowlands
Journal:  J Vasc Interv Radiol       Date:  2002-09       Impact factor: 3.464

View more
  2 in total

1.  A computer-simulated liver phantom (virtual liver phantom) for multidetector computed tomography evaluation.

Authors:  Yoshinori Funama; Kazuo Awai; Osamu Miyazaki; Yoshiharu Nakayama; Da Liu; Taiga Goto; Yasuyuki Yamashita; Shinichi Hori
Journal:  Eur Radiol       Date:  2005-10-20       Impact factor: 5.315

2.  Portal Vein/Aorta Ratio in Dogs with Acquired Portosystemic Collaterals.

Authors:  Y Sakamoto; M Sakai; T Watari
Journal:  J Vet Intern Med       Date:  2017-08-14       Impact factor: 3.333

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.