OBJECTIVE: To assess the diagnostic accuracy of MR imaging for detecting bone marrow infiltration by malignant lymphoma. PATIENTS AND DESIGN: Fifty-three patients with malignant lymphoma underwent MR imaging and bone marrow biopsy. In 80 iliac crests of the 53 patients (13 positive specimens in 9 patients and 67 negative specimens in 44 patients), biopsy results and the signal intensity characteristics were compared. MR sequences included T1-weighted SE, T2-weighted FSE with fat suppression, FSE STIR, and diffusion-weighted EPI with fat suppression at 1.5 T. RESULTS AND CONCLUSIONS: To detect lymphoma infiltration, T1-weighted SE had the highest sensitivity (92%) and diffusion-weighted EPI with fat suppression and FSE STIR had the highest specificity (92.5% and 92%, respectively). A combination of T1-weighted SE and FSE STIR yielded the highest sensitivity and specificity (85% and 97%, respectively). A combination of T1-weighted SE and FSE STIR sequences seems to be the current choice of imaging protocol for detecting bone marrow infiltration by malignant lymphoma.
OBJECTIVE: To assess the diagnostic accuracy of MR imaging for detecting bone marrow infiltration by malignant lymphoma. PATIENTS AND DESIGN: Fifty-three patients with malignant lymphoma underwent MR imaging and bone marrow biopsy. In 80 iliac crests of the 53 patients (13 positive specimens in 9 patients and 67 negative specimens in 44 patients), biopsy results and the signal intensity characteristics were compared. MR sequences included T1-weighted SE, T2-weighted FSE with fat suppression, FSE STIR, and diffusion-weighted EPI with fat suppression at 1.5 T. RESULTS AND CONCLUSIONS: To detect lymphoma infiltration, T1-weighted SE had the highest sensitivity (92%) and diffusion-weighted EPI with fat suppression and FSE STIR had the highest specificity (92.5% and 92%, respectively). A combination of T1-weighted SE and FSE STIR yielded the highest sensitivity and specificity (85% and 97%, respectively). A combination of T1-weighted SE and FSE STIR sequences seems to be the current choice of imaging protocol for detecting bone marrow infiltration by malignant lymphoma.
Authors: Nicholas Bhojwani; Peter Szpakowski; Sasan Partovi; Martin H Maurer; Ulrich Grosse; Hendrik von Tengg-Kobligk; Lisa Zipp-Partovi; Nathan Fergus; Christos Kosmas; Konstantin Nikolaou; Mark R Robbin Journal: Quant Imaging Med Surg Date: 2015-10
Authors: Andreas H Mahnken; Joachim E Wildberger; Gerhard Adam; Sven Stanzel; Thomas Schmitz-Rode; Rolf W Günther; Arno Buecker Journal: Eur Radiol Date: 2005-03-18 Impact factor: 5.315
Authors: Thomas C Kwee; Taro Takahara; Malou A Vermoolen; Marc B Bierings; Willem P Mali; Rutger A J Nievelstein Journal: Pediatr Radiol Date: 2010-07-30