Literature DB >> 11980862

Correction for the erroneous compensation of anterior segment birefringence with the scanning laser polarimeter for glaucoma diagnosis.

David F Garway-Heath1, Michael J Greaney, Joseph Caprioli.   

Abstract

PURPOSE: To evaluate whether erroneous compensation for anterior segment retardation can be estimated and used to correct peripapillary (PP) retinal nerve fiber layer (RNFL) retardation measurements.
METHODS: Retardation measurements (for the 780-nm wavelength), given as RNFL thickness by the scanning laser polarimeter, were obtained at the macula and PP retina in 45 eyes of 45 normal subjects and 53 eyes of 53 patients with early glaucoma. The correlation of macula and PP retardation was assessed. The normal range for RNFL retardation was defined as 97.5th minus 2.5th percentile (normal subjects). This was calculated for uncorrected PP RNFL retardation and for PP RNFL retardation corrected by retardation measurements taken in the macula (analysis 1) and in the temporal aspect of the PP measurement annulus (analysis 2). Further ranges were defined at different percentile cutoffs, and normal and glaucomatous eyes were classified as abnormal if retardation measurements were below each cutoff. The accuracy of classification by uncorrected and corrected measurements was assessed by receiver operating characteristic curve analysis. Uncorrected and corrected RNFL retardation was correlated with visual field mean deviation (MD).
RESULTS: PP retardation correlated significantly with of macular retardation in normal (r(2) = 0.71, P < 0.000) and glaucomatous (r(2) = 0.41, P < 0.000) eyes. The normal range for uncorrected PP retardation was 25.4 degrees and for corrected retardation, 18.0 degrees (analysis 1) and 14.6 degrees (analysis 2), a reduction of 29% and 43%, respectively. For a specificity of 85%, the sensitivity to identify glaucomatous eyes of uncorrected and corrected (analyses 1 and 2) retardation was 26%, 55%, and 66%, respectively. Corrected PP retardation measurements correlated better with visual field MD (analysis 1: r(2) = 0.21; analysis 2: r(2) = 0.18) than did uncorrected measurements (r(2) = 0.05).
CONCLUSIONS: Erroneously corrected anterior segment birefringence significantly affects PP RNFL retardation measurements. Retardation arising from the cornea-corneal compensator interaction can be partially estimated from the macula and temporal aspect of the PP measurement annulus, allowing correction of PP RNFL retardation. This provides a narrower normal range and greater sensitivity for glaucoma diagnosis.

Entities:  

Mesh:

Year:  2002        PMID: 11980862

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  14 in total

1.  Comparison of algorithms for detection of localised nerve fibre layer defects using scanning laser polarimetry.

Authors:  F A Medeiros; R Susanna
Journal:  Br J Ophthalmol       Date:  2003-04       Impact factor: 4.638

2.  Influence of LASIK on scanning laser polarimetric measurement of the retinal nerve fibre layer with fixed angle and customised corneal polarisation compensation.

Authors:  G Holló; A Katsanos; P Kóthy; A Kerek; I Süveges
Journal:  Br J Ophthalmol       Date:  2003-10       Impact factor: 4.638

3.  Scanning laser polarimetry in myopic and hyperopic subjects.

Authors:  Stephan Kremmer; Thomas Zadow; Klaus-Peter Steuhl; J Michael Selbach
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2004-03-17       Impact factor: 3.117

4.  Scanning laser polarimetry with variable and enhanced corneal compensation in normal and glaucomatous eyes.

Authors:  Mitra Sehi; Delia C Guaqueta; William J Feuer; David S Greenfield
Journal:  Am J Ophthalmol       Date:  2006-10-25       Impact factor: 5.258

5.  Relationship between foveal birefringence and visual acuity in neovascular age-related macular degeneration.

Authors:  A Weber; A E Elsner; M Miura; S Kompa; M C Cheney
Journal:  Eye (Lond)       Date:  2006-01-06       Impact factor: 3.775

6.  An enhancement module to improve the atypical birefringence pattern using scanning laser polarimetry with variable corneal compensation.

Authors:  M Sehi; D C Guaqueta; D S Greenfield
Journal:  Br J Ophthalmol       Date:  2006-02-15       Impact factor: 4.638

7.  Quantitative analysis of axonal loss in band atrophy of the optic nerve using scanning laser polarimetry.

Authors:  M L R Monteiro; F A Medeiros; M R Ostroscki
Journal:  Br J Ophthalmol       Date:  2003-01       Impact factor: 4.638

8.  Effect of change in macular birefringence imaging protocol on retinal nerve fiber layer thickness parameters using GDx VCC in eyes with macular lesions.

Authors:  Tanuj Dada; Sana I Tinwala; Vivek Dave; Anand Agarwal; Reetika Sharma; Meenakshi Wadhwani
Journal:  Int Ophthalmol       Date:  2014-01-28       Impact factor: 2.031

9.  Glaucoma classification model based on GDx VCC measured parameters by decision tree.

Authors:  Mei-Ling Huang; Hsin-Yi Chen
Journal:  J Med Syst       Date:  2009-07-04       Impact factor: 4.460

10.  Linear discriminant analysis and artificial neural network for glaucoma diagnosis using scanning laser polarimetry-variable cornea compensation measurements in Taiwan Chinese population.

Authors:  Mei-Ling Huang; Hsin-Yi Chen; Wei-Cheng Huang; Yi-Yu Tsai
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2009-12-15       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.